UST4C11 - UST4C11 ST4-C11 PANASONIC Controller for ST4
Disponibile Prodotto più richiesto

UST4C11

UST4C11 ST4-C11 PANASONIC Controller for ST4

$0.00USD
3452 in magazzino
Specifiche chiave
Articolo:Specifications
PFHD:Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFD:More than 100 years (Note:Mean time to dangerous failure (in years))
Peso:Net weight: 180 g approxGross weight: 390 g approx
Informazioni fornitore
PANASONIC
PANASONIC
Prodotti: 4316
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
ArticoloSpecifications
PFHDRefer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFDMore than 100 years (Note:Mean time to dangerous failure (in years))
PesoNet weight: 180 g approxGross weight: 390 g approx
DettagliController
ProdottoCompact Type 4 Safety Beam Sensor
MaterialeEnclosure: ABS
Numero di parteST4-C11
Nome del prodottoCompact Type 4 Safety Beam Sensor ST4
Cavo di cablaggioTerminal block connector: 0.2 to 1.5 mm2
Tensione di alimentazione24 V DC +10-15 % Ripple P-P 10 % or less
Tempo di rispostaOFF response: 25 ms or lessON response: 90 ms or less (auto reset) / 140 ms or less (manual reset)
Numero di prodottoST4-C11
Uscite ausiliariePNP open-collector transistor / NPN open-collector transistor (Set using output polarity selection switch)ST4-C11: one outputST4-C12EX: four outputs[PNP output]Maximum source current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and +V)Residual voltage: 2.5 V or less (at 100 mA source current)[NPN output]Maximum sink current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and 0 V)Residual voltage: 2.0 V or less (at 100 mA sink current)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Uscita lampada di silenziamento-(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Terminale di collegamentoDetachable spring-cage terminal
Consumo attuale100 mA or less (excluding sensor head ST4-Ax)
Norme applicabiliIEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the controller is used in combination with the sensor head ST4-x.
Testa del sensore applicabileST4-Ax
Conformità alla direttiva sulla marcatura CEMachinery Directive, EMC Directive, RoHS Directive
Uscite ausiliarie: Modalità di funzionamentoOFF when all beams of the connected ST4-Axs are receivedON when one or more beams of the connected ST4-Axs are interrupted
Uscite di controllo (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor Dual output x 1 system (Set using output polarity selection switch)[PNP output]Maximum source current: 200 mAApplied voltage: same as the supply voltage (between control output and +V)Residual voltage: 2.5 V or less (at 200 mA source current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. source current)Load wiring resistance: 3 Ohm or less (between control output and load)[NPN output]Maximum sink current: 200 mAApplied voltage: same as the supply voltage (between control output and 0 V)Residual voltage: 2.0 V or less (at 200 mA sink current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. sink current)Load wiring resistance: 3 Ohm or less (between control output and load)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Uscite ausiliarie: Circuito di protezioneIncorporated
Uscita lampada di silenziamento: circuito di protezioneIncorporated
Resistenza ambientale: umidità ambientale30 to 85 % RH, Storage: 30 to 95 % RH
Resistenza ambientale: resistenza agli urti300 m/s2acceleration in X, Y and Z directions three times each
Resistenza ambientale: temperatura ambiente-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉
Resistenza ambientale: Grado di protezioneEnclosure: IP40 (IEC)Terminal: IP20 (IEC)
Resistenza ambientale: resistenza alle vibrazioni10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each<
Resistenza ambientale: Resistenza di isolamento20 MOhm or more with 500 V DC mega between all supply terminals connected together and enclosure
Uscite di controllo (OSSD 1, OSSD 2): Modalità di funzionamentoON when all beams of the connected ST4-Axs are receivedOFF when one or more beams of the connected ST4-Axs are interruptedOFF during lockout
Testa del sensore applicabile: numero di connessioni in serieInterference prevention possible when up to a maximum of 6 sets are connected(When the maximum of 3 controllers are connected together, interference prevention is possible for up to 18 sets)
Uscite di controllo (OSSD1, OSSD2): Circuito di protezioneIncorporated
Resistenza ambientale: Sopportabilità della tensione1,000 V AC for one min. between all supply terminals connected together and enclosure

Descrizione del prodotto

Standard Control Unit Safety Barrier Category 4 Ple SIL 3, ST4 Series