| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 0.15 mm23-core oil, heat and cold resistant cabtyre cable, 1 m3.281 ftlong |
| Produzione | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 100 mA sink current) |
| Dettagli | NPN output |
| Prodotto | Rectangular-shaped Inductive Proximity Sensor |
| Materiale | Enclosure: PBTIndicator part: Polyester |
| Isteresi | 20 % or less of operation distance(with standard sensing object) |
| Peso netto | 20 g approx. |
| Protezione | IP68 (IEC), IP68g (JEM)(Note) Panasonic Electric Works SUNX's IP68 test method1. Immerse at 0 m below 0 ℃+32 ℉water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃+158 ℉water surface and leave for 30 min.2. Regard the heat shock test in 1 as one cycle and perform 20 cycles.3. Leave in water at a depth of 1 m3.281 ftin water for 500 hours.4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values.(Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. |
| Numero di parte | GX-H8B |
| Nome del prodotto | Rectangular-shaped Inductive Proximity Sensor GX-F/H |
| Ripetibilità | Along sensing axis, perpendicular to sensing axis: 0.04 mm0.002 inor less |
| Numero di prodotto | GX-H8B |
| Tensione di alimentazione | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less |
| Prolunga del cavo | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Umidità ambientale | 45 to 85 % RH, Storage: 35 to 95 % RH |
| Resistenza agli urti | 10,000 m/s2acceleration (1,000 G approx.) in X, Y and Z directions three times each |
| Temperatura ambiente | -25 to +70 ℃-13 to +158 ℉, Storage: - 40 to +85 ℃- 40 to +185 ※ |
| Consumo attuale | 15 mA or less |
| Indicatore di funzionamento | Orange LED(lights up when the output is ON) |
| Intervallo di rilevamento stabile | 0 to 2.1 mm0 to 0.083 in(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
| Resistenza alle vibrazioni | 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude (Max. 20 G) in X, Y and Z directions for two hours each |
| Resistenza di isolamento | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Distanza massima di funzionamento | 2.5 mm0.098 inplus or minus 8 %(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. |
| Frequenza di risposta massima | 500 Hz |
| Output:Operazione di output | Normally closed |
| Oggetto di rilevamento standard | Iron sheet 15 × 15 × t 1 mm0.591 × 0.591 × t 0.039 in |
| Resistenza alla tensione | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Output:Categoria di utilizzo | DC-12 or DC-13 |
| Normative e certificazioni applicabili | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Variazione del campo di rilevamento: caratteristiche della tensione | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage |
| Variazione del campo di rilevamento: caratteristiche della temperatura | Over ambient temperature range -25 to +70 ℃-13 to +158 ℉: Within plus or minus 8 % of sensing range at +23 ℃+73 ℉ |
Specifiche tecniche e dati di prestazione