| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 0.3 mm23-core oil resistant cabtyre cable, 1 m3.281 ftlong |
| Produzione | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
| Peso | Net weight : 45 g approx. |
| Dettagli | GL-18H/18HL type |
| Prodotto | Compact & Low Price Inductive Proximity Sensor |
| Materiale | Enclosure: Polyarylate |
| Isteresi | 15 % or less of operation distance (with standard sensing object) |
| Protezione | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.Please check the resistivity of the sensor against the cutting oil you are using beforehand.) |
| Accessori | - |
| Numero di parte | GL-18H |
| Nome del prodotto | Compact & Low Price Inductive Proximity Sensor GL |
| Numero di prodotto | GL-18H |
| Tensione di alimentazione | 10 to 30 V DC Ripple P-P 10 % or less |
| Prolunga del cavo | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Umidità ambientale | 45 to 85 % RH, Storage: 45 to 85 % RH |
| Resistenza agli urti | 1,000 m/s2acceleration (100 G approx.) in X, Y and Z directions three times each |
| Temperatura ambiente | -25 to +70 ℃-13 to +158℉,Storage: -25 to +70 ℃-13 to +158℉ |
| Consumo attuale | 10 mA or less |
| Indicatore di funzionamento | Red LED (lights up when the output is ON) |
| Intervallo di rilevamento stabile | 0 to 4 mm0 to 0.157 in(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
| Resistenza alle vibrazioni | 10 to 55 Hz frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| Resistenza di isolamento | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Distanza massima di funzionamento | 5 mm0.197 in± 10 %(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
| Frequenza di risposta massima | 1kHz |
| Output:Operazione di output | Normally open |
| Oggetto di rilevamento standard | Iron sheet 25 × 25 × t 1 mm0.984 × 0.984 × t 0.039 in |
| Resistenza alla tensione | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Output:Categoria di utilizzo | DC-12 or DC-13 |
| Conformità alla direttiva sulla marcatura CE | EMC Directive, RoHS Directive |
| Resistenza ambientale: Grado di inquinamento | 3 (Industrial environment) |
| Variazione del campo di rilevamento: caratteristiche della tensione | Within ±2% for ±10 % fluctuation of the supply voltage |
| Variazione del campo di rilevamento: caratteristiche della temperatura | Over ambient temperature range -25 to +70 ℃-13 to +158℉: within ±10 % of sensing range at +20 ℃+68℉ |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo