Orario di servizio: Lunedì a Venerdì 9:00-18:00
WM14DINAV53LR2XXAX - WM14DINAV53LR2XXAX CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING DIN Rail POWER SUPPLY..
Disponibile Prodotto più richiesto

WM14DINAV53LR2XXAX

WM14DINAV53LR2XXAX CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING DIN Rail POWER SUPPLY..

$0.00USD
4536 in magazzino
Informazioni fornitore
CARLO GAVAZZI
CARLO GAVAZZI
Prodotti: 10094
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Descrizione del prodotto

Three-Phase Power Analyzer, Built-in Programming Keypad, Advanced Version, Din Rail
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Dettagli tecnici

Energy ManagementPower AnalyzerType WM14 DIN “Advanced version”• Protection degree (front): IP40• 2 digital outputs• 16 freely configurable alarms with OR/AND logic linkable with up to 2 digital outputs• RS422/485 serial output (MODBUS-RTU), iFIX SCADAcompatibilityProduct Description• Class 1 (kWh), Class 2 (kvarh)• Accuracy ±0.5 F.S. (current/voltage)• Power Analyzer• Instantaneous variables read-out: 3 DGT• Energies readout: 8+1 DGT• System variables: VLL, VLN, An, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmdmax, var, PF, Hz, ASY• Single phase variables: VLL, VLN, VLN min, VLN max, A, Amin, Amax, Admd, VA, W, Wdmd, Wmax, var, PF, PFmin• Harmonic analysis (FFT) up to the 15thharmonic (cur-rent and voltage)• Four quadrant power measurement• Energy measurements: total and partial kWh and kvarh• Hour counter (5+2 DGT)• TRMS meas. of distorted sine waves (voltages/currents)• Universal power supply: 90 to 260 VAC/DC, 18 to 60 VAC/DC• Front dimensions: 107,8x90mm (6 DIN modules)• Voltage asymmetry, phase sequence, phase loss controlHow to order WM14-DIN AV53 H R2 S1 AX3-phase advanced power analyzer with integrated pro- gramming key-pad. Particu- larly recommended for the measurement of the main electrical variables.Housing for DIN-RAIL mount- ing, with RS485 communica- tion port or pulse and/or alarm outputs.Model Range code SystemPower supplyOutput 1Output 2OptionType SelectionRange codesAV5: 380/660VL-L/1/5(6)AAC VL-N: 185 V to 460 VVL-L: 320 V to 800 VAV6: 120/208VL-L/1/5(6)AAC VL-N: 45 V to 145 VVL-L: 78 V to 250 VSystem3 :1, 2 or 3 phase, balanced/unbalanced load, with or without neutralPower supplyOutput 1R2: 2-relay outputsO2: 2-open collector outputsOutput 2XX: NoneS1: RS485/RS422 portOptionsPhase current: 0.03A to 6ANeutral current: 0.09A to 6AL: 18 to 60 VAC/VDCH: 90 to 260 VAC/VDCAX: advanced functionsInputspecificationsRated inputsSystem type: 3 - phaseCurrent3 (by Shunts) Voltage4Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%)1150W-VA-var, FS:230VLN,400VLL AV6: 285W-VA-var, FS:57VLN, 100VLLCurrent 0.25 to 6A: ±(0.5% FS +1DGT)0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current0.25 to 6A: ±(1.5% FS +1DGT)0.09Ato0.25A:±(1.5%FS+7DGT)Phase-phase voltage ±(1.5% FS +1 DGT)Phase-neutral voltage ±(0.5% FS + 1 DGT)Active and Apparent power,0.25 to 6A: ±(1% FS +1DGT)0.03A to 0.25A: ±(1% FS+5DGT)Reactive power 0.25 to 6A: ±(2% FS +1DGT)0.03A to 0.25A: ±(2% FS+5DGT)Active energy Class 1 (start up current: 30mA) Reactive energyClass 2 (start up current: 30mA) Frequency±0.1Hz (48 to 62Hz) Harmonic distortion ±3% F.S. (up to 15th harmonic)(F.S.: 100%)Specifications are subject to change without noticeWM14 DIN A DS ENG230508 1

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo

Top