Specifiche chiave
Articolo:Specifications
Cavo:6–core cabtyre cable, 5 m16.404 ftlong
Osservazione:Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃+73 ℉.■Transponder specificationsOperating frequency: 125 kHzMax. transmitter output: 3.33 μW
Peso:Switch body (standard): 180 g approx., Actuator : 20 g approx.
Informazioni fornitore
PANASONIC
PANASONIC
Prodotti: 4316
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
ArticoloSpecifications
Cavo6–core cabtyre cable, 5 m16.404 ftlong
OsservazioneWhere measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃+73 ℉.■Transponder specificationsOperating frequency: 125 kHzMax. transmitter output: 3.33 μW
PesoSwitch body (standard): 180 g approx., Actuator : 20 g approx.
DettagliVisible type(High code / Standard)
ProdottoNon-Contact Safety Door Switch
MaterialeSwitch body: PBT, PC, SUS (stainless steel), EPDMActuator: PBT, PC
Numero di parteSG-P2020-M-N
Peso lordo270 g approx.
Nome del prodottoNon-Contact Safety Door Switch SG-P
Tensione di alimentazione24V DC+10-20% Ripple P-P 10 % or less
Tempo di risposta• For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less• For multiple units: Time for single unit + 5 ms x (number of connected units - 1)
Numero di prodottoSG-P2020-M-N
Grado di inquinamento3
Consumo attuale30 mA or less
Controllare l'input e l'outputDedicated communication line between the switch body (standard) and the switch body (sub) (Note)* It is not for external input and output. (voltage range 0 V to 5 V DC)(Note) : When using the device as a single unit, connect the check input with the check output.
Lunghezza del cavo collegato• When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit• When connecting multiple units in series: Maximum total cable length of 100 m328.084 ft, maximum cable length of 20 m65.617 ftbetween two adjacent units
Norme applicabili: GiapponeJIS B 9705-1, JIS C 0508-1 to 3 (SIL3), JIS B 9961, JIS C 8201-5-2, JIS B 9710
Norme applicabili: EuropaEN ISO 13849-1 : 2015 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1
Uscite di controllo (OSSD 1, OSSD 2)NPN open-collector transistor 2 outputs• Maximum sink current: 100 mA• Applied voltage: Same as the power supply voltage (NPN output: between control output and 0 V)• Residual voltage: 2 V or less (source current and sink current: 100 mA) (excluding voltage drop due to cable)• Leakage current: 0.2 mA or less (including power OFF state)• Maximum load capacity: 0.47 μF• Load wiring resistance: 3 Ω or less
Distanza operativa: frontale/lateraleSao (OFF→ON): 5 mm0.197 in, Sar (ON → OFF): 15 mm0.591 in
Norme applicabili: Nord AmericaCAN/CSA C22.2 No.14, UL508
Numero di unità collegate in serie30 units or less (standard 1 unit, sub 29 units)
Uscita di controllo (OSSD): circuito di protezioneIncorporated
Normative e certificazioni applicabiliCE Marking (Machinery Directive, RE Directive, RoHS Directive), UKCA Marking (Supply of Machinery (Safety) Regulations, RE Regulations, RoHS Regulations), TÜV SÜD certification, TÜV SÜD certification (U.S.A., Canada), the U.S.'s radio regulations (FCC) (Note), Canada's radio regulations (ICES-003, RSS-310) (Note), Singapore's radio regulations (IMDA certification) (Note), Thailand's radio regulations (NBTC certification) (Note), Philippines' radio regulations (NTC certification) (Note), Korea's radio regulations (KC certification) (Note), India's radio regulations (WPC certification) (Note)(Note) : This product uses a weak radio signal for its detection operation. Please confirm compliance with applicable laws in the country of use.
Resistenza ambientale: umidità ambientale30 to 85 % RH, storage: 30 to 95 % RH
Resistenza ambientale: resistenza agli urti300 m/s2(approx. 30 G), 3 times each in X, Y, and Z direction
Norme applicabili: Norma internazionaleISO 13849-1 : 2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119
Resistenza ambientale: temperatura ambiente-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +65 ℃-13 to +149 ℉
Resistenza ambientale: Grado di protezioneIP65(IEC)
Resistenza ambientale: resistenza alle vibrazioni10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions
Resistenza ambientale: Resistenza di isolamento20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Uscite di controllo (OSSD 1, OSSD 2): Modalità di funzionamento• When the actuator is detected (safe state): ON• When the actuator is not detected (unsafe state or lockout state): OFF• When the switch body (sub) does not detect actuator (series connection): OFF
Resistenza ambientale: Sopportabilità della tensione1,000 V AC for one minute between all supply terminals connected together and enclosure

Descrizione del prodotto

SG-P2020-M-N_Non-Contact Safety Door Switch_Non-Contact Safety Door Switch SG-P_Visible type(High code / Standard)
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo

Top