| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 6–core cabtyre cable, 5 m16.404 ftlong |
| Osservazione | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃+73 ℉.■Transponder specificationsOperating frequency: 125 kHzMax. transmitter output: 3.33 μW |
| Peso | Switch body (standard): 180 g approx., Actuator : 20 g approx. |
| Dettagli | Visible type(Low code / Standard) |
| Prodotto | Non-Contact Safety Door Switch |
| Materiale | Switch body: PBT, PC, SUS (stainless steel), EPDMActuator: PBT, PC |
| Numero di parte | SG-P1020-M-P |
| Peso lordo | 270 g approx. |
| Nome del prodotto | Non-Contact Safety Door Switch SG-P |
| Tensione di alimentazione | 24V DC+10-20% Ripple P-P 10 % or less |
| Tempo di risposta | • For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less• For multiple units: Time for single unit + 5 ms x (number of connected units - 1) |
| Numero di prodotto | SG-P1020-M-P |
| Grado di inquinamento | 3 |
| Consumo attuale | 30 mA or less |
| Controllare l'input e l'output | Dedicated communication line between the switch body (standard) and the switch body (sub) (Note)* It is not for external input and output. (voltage range 0 V to 5 V DC)(Note) : When using the device as a single unit, connect the check input with the check output. |
| Lunghezza del cavo collegato | • When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit• When connecting multiple units in series: Maximum total cable length of 100 m328.084 ft, maximum cable length of 20 m65.617 ftbetween two adjacent units |
| Norme applicabili: Giappone | JIS B 9705-1, JIS C 0508-1 to 3 (SIL3), JIS B 9961, JIS C 8201-5-2, JIS B 9710 |
| Norme applicabili: Europa | EN ISO 13849-1 : 2015 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1 |
| Uscite di controllo (OSSD 1, OSSD 2) | PNP open-collector transistor 2 outputs• Maximum source current: 100 mA• Applied voltage: Same as the power supply voltage (PNP output: between control output and +V)• Residual voltage: 2 V or less (source current and sink current: 100 mA) (excluding voltage drop due to cable)• Leakage current: 0.2 mA or less (including power OFF state)• Maximum load capacity: 0.47 μF• Load wiring resistance: 3 Ω or less |
| Distanza operativa: frontale/laterale | Sao (OFF→ON): 5 mm0.197 in, Sar (ON → OFF): 15 mm0.591 in |
| Norme applicabili: Nord America | CAN/CSA C22.2 No.14, UL508 |
| Numero di unità collegate in serie | 30 units or less (standard 1 unit, sub 29 units) |
| Uscita di controllo (OSSD): circuito di protezione | Incorporated |
| Normative e certificazioni applicabili | CE Marking (Machinery Directive, RE Directive, RoHS Directive), UKCA Marking (Supply of Machinery (Safety) Regulations, RE Regulations, RoHS Regulations), TÜV SÜD certification, TÜV SÜD certification (U.S.A., Canada), the U.S.'s radio regulations (FCC) (Note), Canada's radio regulations (ICES-003, RSS-310) (Note), Singapore's radio regulations (IMDA certification) (Note), Thailand's radio regulations (NBTC certification) (Note), Philippines' radio regulations (NTC certification) (Note), Korea's radio regulations (KC certification) (Note), India's radio regulations (WPC certification) (Note)(Note) : This product uses a weak radio signal for its detection operation. Please confirm compliance with applicable laws in the country of use. |
| Resistenza ambientale: umidità ambientale | 30 to 85 % RH, storage: 30 to 95 % RH |
| Resistenza ambientale: resistenza agli urti | 300 m/s2(approx. 30 G), 3 times each in X, Y, and Z direction |
| Norme applicabili: Norma internazionale | ISO 13849-1 : 2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119 |
| Resistenza ambientale: temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +65 ℃-13 to +149 ℉ |
| Resistenza ambientale: Grado di protezione | IP65(IEC) |
| Resistenza ambientale: resistenza alle vibrazioni | 10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions |
| Resistenza ambientale: Resistenza di isolamento | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Uscite di controllo (OSSD 1, OSSD 2): Modalità di funzionamento | • When the actuator is detected (safe state): ON• When the actuator is not detected (unsafe state or lockout state): OFF• When the switch body (sub) does not detect actuator (series connection): OFF |
| Resistenza ambientale: Sopportabilità della tensione | 1,000 V AC for one minute between all supply terminals connected together and enclosure |