| Parametro | Valore |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| Cioè | Main circuit, look monitor circuit |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Articolo | Specifications |
| Cavo | UL style 2464, No.22 AWG 12-core |
| Peso | Approx. 600 g |
| Dettagli | Spring lock type |
| Prodotto | Ultra-slim Safety door switch with solenoid interlock |
| Materiale | Enclosure : PA66 |
| Protezione | IP 67 (IEC 60529) |
| Numero di parte | SG-B1-SB-G5 |
| Lunghezza del cavo | 5m16.404 ft |
| Nome del prodotto | Ultra-slim Safety door switch with solenoid interlock SG-B1 |
| Contatti principali | 1NC + 1NC |
| Numero di prodotto | SG-B1-SB-G5 |
| Forza di interblocco | 500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| Resistenza agli urti | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| Resistenza di contatto | 300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Frequenza operativa | 900 operations/hour |
| Norme applicabili | EN 60947-5-1, GS-ET-19 |
| Forza di apertura diretta | 60 N min. |
| Circuito di monitoraggio della porta | AC |
| Resistenza alle vibrazioni | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| Corsa di apertura diretta | 8 mm0.315 inmin. |
| Contatti del monitor della porta | 2NC |
| Durata elettrica | 100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load) |
| Bloccare i contatti del monitor | 1NO |
| Durata meccanica | 1,000,000 operations min. (GS-ET-19) |
| Corrente termica (Ith) | ・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits) |
| Normativa applicabile | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| Carico induttivo (AC-15) | - |
| Carico induttivo (DC-13) | 1A |
| Velocità di funzionamento dell'attuatore | 0.05 to 1.0 m/sec. |
| Tensione nominale di isolamento (Ui) | 300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit) |
| Condizioni operative: Altitudine | 2,000 m6,561.68 ftmax. |
| Classe di protezione contro le scosse elettriche | Class II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| Dispositivo di protezione da cortocircuito | Use 250 V / 10 A fast acting type fuse |
| Tensione di tenuta all'impulso (Uimp) | 2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit) |
| Solenoide / Indicatore: Indicatore | Green LED |
| Solenoide / Indicatore: Corrente nominale | 110 mA (solenoid 100 mA, LED 10 mA : initial value) |
| Condizioni operative: umidità ambiente | 45 to 85 % RH |
| Condizioni operative: Grado di inquinamento | 3 (Inside 2) |
| Solenoide/Indicatore: Accensione della tensione | Rated voltage × 85 % max. (at 20 ℃68 ℉) |
| Solenoide/Indicatore: Spegnere la tensione | Rated voltage × 10 % min. (at 20 ℃68 ℉) |
| Norme applicabili: Norme per l'uso | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| Condizioni operative: temperatura ambiente | -25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Solenoide/Indicatore: Tensione di esercizio nominale | DC 24 V 100% duty cycle |
| Tensione nominale di esercizio (Ue) / Corrente nominale di esercizio (Ie) | Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo