USGB1MAG1 - USGB1MAG1 SG-B1-MA-G1 PANASONIC Safety door switch (Ultra-slim) with solenoid interlock, Magnet lock, 1m cab..
Disponibile Prodotto più richiesto

USGB1MAG1

USGB1MAG1 SG-B1-MA-G1 PANASONIC Safety door switch (Ultra-slim) with solenoid interlock, Magnet lock, 1m cab..

$0.00USD
3389 in magazzino
Specifiche chiave
:Ue
DC:Resistive load (DC-12)
Cioè:Main circuit, look monitor circuit
B10D:2,000,000(ISO 13849-1 Annex C Table C.1)
Informazioni fornitore
PANASONIC
PANASONIC
Prodotti: 4316
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
Ue
DCResistive load (DC-12)
CioèMain circuit, look monitor circuit
B10D2,000,000(ISO 13849-1 Annex C Table C.1)
ArticoloSpecifications
CavoUL style 2464, No.22 AWG 12-core
PesoApprox. 220 g
DettagliMagnet lock type
ProdottoUltra-slim Safety door switch with solenoid interlock
MaterialeEnclosure : PA66
ProtezioneIP 67 (IEC 60529)
Numero di parteSG-B1-MA-G1
Lunghezza del cavo1m3.281 ft
Nome del prodottoUltra-slim Safety door switch with solenoid interlock SG-B1
Contatti principali1NC + 1NC
Numero di prodottoSG-B1-MA-G1
Forza di interblocco500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine.
Resistenza agli urtiMalfunction : 100 m/s2, Destruction : 1,000 m/s2
Resistenza di contatto300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable)
Frequenza operativa900 operations/hour
Norme applicabiliEN 60947-5-1, GS-ET-19
Forza di apertura diretta60 N min.
Circuito di monitoraggio della portaAC
Resistenza alle vibrazioniMalfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in
Corsa di apertura diretta8 mm0.315 inmin.
Contatti del monitor della porta2NC
Durata elettrica100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load)
Bloccare i contatti del monitor1NC
Durata meccanica1,000,000 operations min. (GS-ET-19)
Corrente termica (Ith)・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits)
Normativa applicabileCE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations]
Carico induttivo (AC-15)-
Carico induttivo (DC-13)1A
Velocità di funzionamento dell'attuatore0.05 to 1.0 m/sec.
Tensione nominale di isolamento (Ui)300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit)
Condizioni operative: Altitudine2,000 m6,561.68 ftmax.
Classe di protezione contro le scosse elettricheClass II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more.
Dispositivo di protezione da cortocircuitoUse 250 V / 10 A fast acting type fuse
Tensione di tenuta all'impulso (Uimp)2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit)
Solenoide / Indicatore: IndicatoreGreen LED
Solenoide / Indicatore: Corrente nominale110 mA (solenoid 100 mA, LED 10 mA : initial value)
Condizioni operative: umidità ambiente45 to 85 % RH
Condizioni operative: Grado di inquinamento3 (Inside 2)
Solenoide/Indicatore: Accensione della tensioneRated voltage × 85 % max. (at 20 ℃68 ℉)
Solenoide/Indicatore: Spegnere la tensioneRated voltage × 10 % min. (at 20 ℃68 ℉)
Norme applicabili: Norme per l'usoIEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14
Condizioni operative: temperatura ambiente-25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉
Solenoide/Indicatore: Tensione di esercizio nominaleDC 24 V 100% duty cycle
Tensione nominale di esercizio (Ue) / Corrente nominale di esercizio (Ie)Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A

Descrizione del prodotto

Safety limit switch (Ultra-narrow) for door with interconnection and magnetic lock, 1m cable, main 1NC+1NC, Monitor 2NC+1NC
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo