| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Osservazione | Use the safety light curtain monitoring information obtained via IO-Link only for diagnostic purposes. Do not use it for safety control purposes. |
| Peso | 270 g approx. |
| Prodotto | IO-Link communication unit for safety light curtain SF4D series |
| Materiale | Main unit case: PA66 (with glass)Base plate: SPCC + PlatingProduct model nameplate: PolyesterExternal connection connector: Brass + Plating |
| Funzioni | • IO-Link communication function• Safety light curtain setting data copy function (Note)Note :• The internal memory (nonvolatile) of this product has a service life. Settings cannot be configured more than 100,000 times.• This product cannot be used to directly enter settings from the IO-Link master unit to a safety light curtain using IO-Link communication.• The safety light curtain setting data copy function is designed only for use in maintenance / replace of safety light curtains.Use the copy function only for loading the setting data of the previous safety light curtain to a new unit. Loading the data to a device other than a newly installed safety light curtain may result in improper device operation.• This function cannot be used unless the product is connected with the IO-Link master unit and IO-Link communication is used. |
| Numero di parte | SFD-WL3 |
| Nome del prodotto | IO-Link Communication Unit |
| Numero di prodotto | SFD-WL3 |
| Umidità ambientale | 30 to 85% RH, Storage: 30 to 95% RH |
| Grado di inquinamento | 3 |
| Altitudine operativa | 2,000 m6561.68 ftor lessNote : Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| Temperatura ambiente | -10 to +55℃14 to 131℉(No dew condensation or icing allowed),Storage: -25 to +60℃-13 to 140℉ |
| Grado di protezione | IP64 |
| Normativa applicabile | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Categoria di sovratensione | I |
| Numero di unità collegabili: Questo prodotto | 1 unit |
| Resistenza ambientale: Resistenza agli urti | 300 m/s2acceleration (30 G approx.) in X, Y, and Z directions three times eachMalfunction resistance 100 m/s2acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each |
| Tensione di alimentazione: lato comunicazione IO-Link | 24V DC+20-25% Ripple P-P 10 % or less |
| Metodo di connessione: lato comunicazione IO-Link | 4-core cable with M12 connector (commercially available product) |
| Resistenza ambientale: Resistenza alle vibrazioni | 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions for two hours eachMalfunction resistance 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions twenty times each |
| Consumo di corrente: lato comunicazione IO-Link | 30 mA or less |
| Resistenza ambientale: Resistenza di isolamento | 20 MΩ or more, with 500 V DC megger, between all supply terminals connected together and enclosure |
| Metodo di comunicazione: lato comunicazione IO-Link | IO-Link specifications: Ver. 1.1Baud rate: COM3 (230.4 kbps)Data length: 18 bytes, process data (PD)Minimum cycle time: 1.5 ms |
| Collegamento: lato comunicazione della barriera fotoelettrica di sicurezza | 8-core cable for safety light curtain (optional) |
| Resistenza ambientale: Tensione di rigidità dielettrica | 1,000 V AC for one minute, between all supply terminals connected together and enclosure |
| Tensione di alimentazione: lato comunicazione della barriera fotoelettrica di sicurezza | 24V DC+20-30% Ripple P-P 10 % or less |
| Consumo di corrente: lato comunicazione della barriera fotoelettrica di sicurezza | 15 mA or less |
| Metodo di comunicazione: lato comunicazione della barriera fotoelettrica di sicurezza | RS-485 bidirectional communication (dedicated protocol) |
| Numero di unità collegabili: Barriere fotoelettriche di sicurezza in collegamento in serie | Up to 5 units (total number of beam channels 256 or less) |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo