| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Peso | Net weight: 320 g approx. |
| Dettagli | Connector connection type control unit |
| Prodotto | Exclusive Control Unit for Safety Light Curtain |
| Valore nominale del fusibile | Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down |
| Numero di parte | SF-C11 |
| Nome del prodotto | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| Tensione di alimentazione | 24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain) |
| Tempo di risposta | 10 ms or less |
| Uscita di sicurezza | NO contact × 3 (13-14, 23-24, 33-34) |
| Numero di prodotto | SF-C11 |
| Umidità ambientale | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Grado di inquinamento | 2 |
| Uscite ausiliarie | Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path) |
| Materiale di contenimento | ABS |
| Temperatura ambiente | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉ |
| Terminale di collegamento | Detachable spring-cage terminal |
| Consumo attuale | 100 mA or less (without light curtain) |
| Categoria di sovratensione | II |
| Resistenza alle vibrazioni | Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm0.014 inamplitudein X, Y, and Z directions for twenty times each |
| Funzione di bordo d'uscita | Incorporated |
| Indicatori: Guasto (FAULT) | Yellow LED (blinks when fault occurs) |
| Norme applicabili: Giappone | JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), |
| Funzione di selezione della polarità | Incorporated (Sliding switch allows selection of plus/minus ground)Minus ground: Correspond to PNP output safety light curtainPlus ground: Correspond to NPN output safety light curtain(Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.) |
| Indicatori: Alimentazione (Ui) | Green LED (lights up when the power is ON) |
| Indicatori: Uscita di sicurezza [OUT] | Green LED (lights up when safety output is closed)(Note:The operation indicator is marked as "Enabling" on the unit forSF-C12.) |
| Conformità alla direttiva sulla marcatura CE | Machinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive |
| Funzione di monitoraggio del relè esterno | Incorporated |
| Norme applicabili: Europa (UE) | EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), ISO 13849-1 (Category 4, PLe) |
| Uscita di sicurezza: resistenza di contatto | 100 mOhm or less (initial value) |
| Barriere fotoelettriche di sicurezza collegabili | SF4D / SF4B / SF4B-G / SF2Bseries |
| Indicatori: Interblocco (INTER_LOCK) | Yellow LED (lights up when safety output is opened) |
| Uscita di sicurezza: durata elettrica | 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| Uscita di sicurezza: durata meccanica | 10,000,000 times or more (open/close frequency of 180 times/min)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| Norme applicabili: Nord America | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note:SF-C11andSF-C13comply with UL 1998 (Class 2).) |
| Uscita di sicurezza: Categoria di applicazione | AC-15, DC-13 (IEC 60947-5-1) |
| Uscita ausiliaria a semiconduttore (AUX) | <Minus ground (Setting for PNP)>PNP open-collector transistor・Max. source current: 60 mA・Applied voltage: sameas supply voltage(between the semiconductor auxiliary output and +V)・Residual voltage: 2.3 V or less (at source current 60 mA)Leakage current: 2 mA or less<Plus ground (Setting for NPN)>NPN open-collector transistor・Max. sink current: 60 mA・Applied voltage: same as supply voltage(between the semiconductorauxiliary output and 0 V)・Residual voltage: 1.5 V or less(at sink current 60 mA)Leakage current: 2 mA or less |
| Ritardo di ripresa (ripristino automatico / ripristino manuale) | 80 ms or less / 90 ms or less |
| Uscita di sicurezza: Materiale di contatto / contatti | AgSnO, self cleaning, positively driven |
| Norme applicabili: Norma internazionale | IEC 61496-1 (Type 4) |
| Uscita di sicurezza: fusibile di protezione dei contatti nominale | 6 A (slow blow) |
| Resistenza ambientale: Grado di protezione | Enclosure: IP40Terminal: IP20 |
| Uscita ausiliaria: fusibile di protezione del contatto nominale | 2 A (slow blow) |
| Uscita ausiliaria: tensione/corrente di funzionamento nominale | 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) |
| Uscita ausiliaria a semiconduttore (AUX): funzionamento dell'uscita | Related to auxiliary output of safety light curtain |
| Uscita di sicurezza: tensione di funzionamento nominale (Ue) / corrente di funzionamento nominale (le) | 6 A / 30 V DC, 6 A / 230 V AC, resistive load (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC)(Note:If severalSF-C11orSF-C13units are being used in a line together, leavea space of 5 mm0.197 inor more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below.) |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo