| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| PFHD | 3.62 × 10-9 |
| Cavo | 0.15mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m16.404 ftlong |
| MTTFD | 100 years or more |
| Dettagli | Min. sensing object ø14 mmø0.551 intype (10 mm0.394 inbeam pitch) [Cable type] |
| Prodotto | Ultra-slim Safety Light Curtain [Type 4 PLe SIL3] |
| Materiale | Enclosure: Polycarbonate alloySensing surface: Polycarbonate alloy |
| Passo del fascio | 10 mm0.394 in |
| Accessori | MS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR14 (Test rod): 1 No. |
| Numero di parte | SF4C-F39 |
| Nome del prodotto | Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C |
| Funzione ELCA | Incorporated (reducing mutual interference automatically) |
| Tensione di alimentazione | 24 V DC +10-15 % Ripple P-P 10 % or less |
| Tempo di risposta | OFF response: 9 ms or lessON response: 90 ms or less |
| Numero di prodotto | SF4C-F39 |
| Prolunga del cavo | Extension up to 40.5 m132.874 ftis possible for both emitter and receiver, with 0.2 mm2or more cable.(Note) When the muting lamp is used, the cable can be extended within 30.5 m100.066 ft(for emitter / receiver). |
| Funzione di disattivazione audio | Incorporated |
| Gamma operativa | 0.1 to 3 m0.328 to 9.843 ft(Note) The operating range is the possible setting distance between the emitter and the receiver. |
| Elemento emittente | Infrared LED (Peak emission wavelength: 855 nm0.034 mil) |
| Grado di inquinamento | 3 |
| Funzione di override | Incorporated |
| Altezza di protezione | 400 mm15.748 in |
| Funzione di interblocco | Incorporated [Manual reset / Automatic reset (Note)](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
| Altitudine operativa | 2,000 m6,561 68 ftor less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.) |
| Funzioni opzionali | Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting(Note) In case of using optional function, the handy-controller SFC-HC is required. |
| Illuminazione ambientale | Incandescent light: 5,000 lx or less at the light-receiving face |
| Oggetto di rilevamento minimo | ø14 mmø0.551 inopaque object(Note) When the floating blanking function is used, the size of the min. sensing object is changed. |
| Numero di canali del fascio | 39 |
| Funzione di input di sicurezza | Incorporated (safety contact) |
| Angolo di apertura effettivo | plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2)] |
| Norme applicabili: Giappone | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3(SIL3) |
| Norme applicabili: Europa | EN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL 3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| Funzione di test/reset dell'input | Incorporated |
| Uscite di controllo (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 200 mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less[When selecting NPN output]- Max. sink current: 200 mA- Applied voltage: same as supply voltage (between the control output and 0 V)- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less |
| Norme applicabili: Nord America | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
| Funzione di monitoraggio del dispositivo esterno | Incorporated |
| Uscita ausiliaria (uscita non di sicurezza) | PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and +V)- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m32.808 ftlength cable)[When selecting NPN output]- Max. sink current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m32.808 ftlength cable) |
| Normative e certificazioni applicabili | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification |
| Resistenza ambientale: umidità ambientale | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Resistenza ambientale: resistenza agli urti | 300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Peso netto (totale di emettitore e ricevitore) | 800 g approx. |
| Norme applicabili: Norma internazionale | IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL 3) |
| Resistenza ambientale: temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉ |
| Resistenza ambientale: Grado di protezione | IP67 / IP65 (IEC) |
| Resistenza ambientale: resistenza alle vibrazioni | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Resistenza ambientale: Resistenza di isolamento | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Uscite di controllo (OSSD 1, OSSD 2): Modalità di funzionamento | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.(Note) In case the blanking function is valid, the operation mode is changed. |
| Uscite di controllo (OSSD1, OSSD2): Circuito di protezione | Incorporated |
| Resistenza ambientale: Sopportabilità della tensione | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Uscita ausiliaria (uscita non di sicurezza): modalità di funzionamento | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller). |
| Uscita ausiliaria (uscita non di sicurezza): circuito di protezione | Incorporated |
| Consumo di corrente: grande indicatore multifunzione si illumina | Emitter: 115 mA or lessReceiver: 120 mA or less |
| Consumo di corrente: Grandi spie luminose multifunzione spente | Emitter: 80 mA or lessReceiver: 90 mA or less |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo