| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 0.3 mm25-core cabtyre cable, 0.5 m1.640 ftlong (for input and output) |
| Peso | Net weight: 210 g approx.Gross weight: 390 g approx. |
| Dettagli | Main sensors(Standard model / Short sensing range) |
| Prodotto | Long Range & Wide Area Photoelectric Sensor |
| Materiale | Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate |
| Accessorio | MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc. |
| Isteresi | 15 % or less of operation distance(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm11.811 × 11.811 in) as the object.) |
| USCITA 1, USCITA 2 | NPN open-collector transistor・Maximum sink current: 100 mA・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V)・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)* OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas)OUT2(OR circuit among the effective center, left and right OUT 2 areas) |
| Protezione | IP65 (IEC) |
| Numero di parte | PX-21 |
| Nome del prodotto | Long Range & Wide Area Photoelectric Sensor PX-2 |
| Area di rilevamento | Four sensing areas are selectable with dip switches. |
| Tempo di risposta | 80 ms or less |
| Numero di prodotto | PX-21 |
| Funzione sonno | Operating / sleep selectable with external input |
| Tensione di alimentazione | 10 to 31 V DC including ripple |
| Prolunga del cavo | Extension up to total 100 m328.084 ft(10 m32.808 ftfor auxiliary sensor connection) is possible with 0.3 mm2, or more, cable. |
| Umidità ambientale | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Elemento emittente | Infrared LED (Peak emission wavelength: 950 nm0.037 mil, modulated) |
| Resistenza agli urti | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Consumo energetico | Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor)(Note:Obtain the current consumption by the following calculation.Current consumption = Power consumption ÷ Supply voltage(e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA) |
| Illuminazione ambientale | Incandescent light: 3,000 lx or less at the light-receiving face |
| Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -20 to +70 ℃-4 to +158 ℉ |
| Regolatore di sensibilità | Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.) |
| Resistenza alle vibrazioni | 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude (20 G max.) in X, Y and Z directions for two hours each |
| Resistenza di isolamento | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Resistenza alla tensione | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| OUT1, OUT2: funzionamento dell'uscita | Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.) |
| Conformità alla direttiva sulla marcatura CE | EMC Directive, RoHS Directive |
| Indicatori di funzionamento: area OUT 1 | Red LED (lights up when the beam is received in the effective OUT 1 areas) |
| Indicatori di funzionamento: area OUT 2 | Yellow LED (lights up when the beam is received in the effective OUT 2 areas) |
| OUT1, OUT2: Protezione da cortocircuito | Incorporated |
| Campo di rilevamento (aree OUT 1 e OUT 2) | 1 m3.281 ft(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm11.811 × 11.811 in) as the object.) |
| Funzione di prevenzione automatica delle interferenze | Optical interference from up to 25 units is prevented. |
Specifiche tecniche e dati di prestazione