| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Tipo | Sensing width 10 mm0.394 intype |
| Cavo | 0.09mm23-core shielded cable with connector, 0.5 m1.640 ftlong |
| Peso | Emitter: 30 g approx.Receiver: 20 g approx. |
| Dettagli | Sensor head (Sensing width 10 mm0.394 intype) |
| Prodotto | Ultra-compact Laser Collimated Beam Sensor |
| Materiale | Enclosure: PolyetherimideCase cover: PolycarbonateFront cover: Glass |
| Accessorio | MS-LA3-1 (Sensor head mounting bracket): One set of two brackets for both the emitter and the receiverCN-HLT1-1 (Sensor head to controller connection cable): 1 cableLaser beam alignment sticker: 2 pcs.Label set (FDA regulations conformed type only): 1 set |
| Numero di parte | HL-T1010A |
| Nome del prodotto | Ultra-compact Laser Collimated Beam Sensor HL-T1 |
| Campo di rilevamento | ■■【In the case of(0 to 500 mm 0to 19.685 in)】■■Sensing width:ø1 mmø0.039 inMin. sensing object:ø8 micro mø0.315 milopaque objectRepeatability (During the state in which light is half blocked):4 micro m0.157 mil(Note:In case of an average sampling rate of 64 times.)Linear output resolution:4 micro m0.157 mil(Note) In case of an average sampling rate of 64 times.(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mmø0.039 in.)■■【In the case of (500 to 2,000 mm19.685 to 78.74 in)】■■Sensing width:ø1 to ø2.5 mmø0.039 to ø0.098 inMin. sensing object:ø50 micro mø1.969 milopaque objectRepeatability (During the state in which light is half blocked): -Linear output resolution: -- |
| Numero di prodotto | HL-T1010A |
| Prolunga del cavo | Extension up to total 10 m32.808 ftis possible, with the optional cable. |
| Grado di inquinamento | 3 (industrial environment) |
| Indicatore di emissione | Green LED (lights up during laser emission) |
| Controller applicabile | HL-AC1, HL-AC1P |
| Resistenza di isolamento | 100 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Resistenza alla tensione | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Conformità alla direttiva sulla marcatura CE | EMC Directive, RoHS Directive |
| Funzione di prevenzione delle interferenze | Two units of sensors can be mounted close together. (When the controller interference prevention function is used) |
| Resistenza ambientale: Umidità ambientale | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Resistenza ambientale: Resistenza agli urti | 300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Resistenza ambientale: Illuminazione ambientale | Incandescent light: 10,000 liter x or less at the light-receiving face |
| Resistenza ambientale: Temperatura ambiente | 0 to +50 ℃+32 to +122 ℉(No dew condensation allowed), Storage: -25 to +65 ℃-13 to +149 ℉ |
| Resistenza ambientale: Resistenza alle vibrazioni | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| Elemento emittente: tipo conforme alle normative FDA | Red semiconductor laser Class II (FDA)(modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm0.026 mil)(IEC / JIS: Class 1) |
| Elemento emittente: tipo conforme agli standard IEC/JIS | Red semiconductor laser Class 1 (IEC / JIS)(modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm0.026 mil) |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo