Specifiche chiave
Articolo:Specifications
Peso:450 g approx.
Dettagli:Controller
Prodotto:Ultra High-speed High-precision Laser Displacement Sensor
Informazioni fornitore
PANASONIC
PANASONIC
Prodotti: 4316
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
ArticoloSpecifications
Peso450 g approx.
DettagliController
ProdottoUltra High-speed High-precision Laser Displacement Sensor
MaterialeCase: Polycarbonate
AccessorioUSB cable (2 m 6.562 ft long): 1 pc.Short bracket: 1 pc.
Numero di parteHL-C2C-P
Reimposta inputReset is done when connected to external power (+).Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Uscita allarmePNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less(between alarm output and +V)- Residual voltage: 1 V or less(at 100 mA source current)
Nome del prodottoUltra High-speed・High-precision Laser Displacement Sensor HL-C2
Input di temporizzazioneON at/during connection to external power (+)(depending on analysis mode)Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Frequenza di campionamento10 micro s, 20 micro s, 40 micro s, 100 micro s, 200 micro s, 400 micro s, 1 ms, 2 ms
Uscita stroboscopicaPNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less(between strobe output to +V)- Residual voltage: 1 V or less(at 100 mA source current)
Numero di prodottoHL-C2C-P
Tensione di alimentazione24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Ingresso a zeroZero set is ON when connected with external power (+).Zero set turns to OFF after continuously connected to external power (+) for one second.Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Indicatore: PotenzaGreen LED (lights up at power on)
Consumo attuale500 mA approx. at 2 sensor heads connected350 mA approx. at 1 sensor head connected(100 mA approx. is additionally required when the mini console is connected)
Indicatore: Allarme 1Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Indicatore: Allarme 2Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
Ingresso di controllo laserLaser emission is stopped when connected to external power (+).Laser is emitted immediately after opened.Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Input di modifica della memoriaMemory is specified when connected to external power (+).Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Testa del sensore ConnectaleNumber of connectable units: Max. 2 units.
Ingresso di interblocco remotoLaser emission is delayed when connected to IL (+).Laser emission stop at openApplied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Uscita analogica: correnteCurrent output scale: 4 to 20 mA/F.S (initial value)Output range during normal status: 2 to 24 mAOutput at abnormal status: 1 mA or 25 mAResolution: 3 micro A, Linearity plus or minus 0.05% F.S.Load impedance: 250 Ohm max., Response delay time: 10 micro s approx.(Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
Uscita analogica: tensioneVoltage output scale: -5 to +5 V/F.S (initial value)Output range during normal status: -10.0 to +10.0 VOutput at abnormal status: -10.8 V or +10.8 VResolution: 2 mV, Linearity: plus or minus 0.05 % F.S.Max. 2 mA, output impedance 50 Ohm , Response delay time: 1.5 micro s/V approx.(Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Output del giudizio (HI, GO, LO)PNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less(between judgment output to +V)- Residual voltage: 1 V or less(at 100 mA source current)
Uscita allarme: funzionamento dell'uscitaOpened when the amount of light is insufficient
Uscita stroboscopica: funzionamento dell'uscitaOpened at data determination
Uscita allarme: protezione da cortocircuitoIncorporated
Uscita stroboscopica: protezione da cortocircuitoIncorporated
Indicatore: Testa del sensore A Radiazione laserGreen LED (lights up during or immediately before laser emission of sensor head A)
Indicatore: Testa del sensore B Radiazione laserGreen LED (lights up during or immediately before laser emission of sensor head B)
Resistenza ambientale: Umidità ambientale35 to 85 %RH
Resistenza ambientale: Resistenza agli urti196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Resistenza ambientale: Temperatura ambiente0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Uscita di giudizio (HI, GO, LO): operazione di uscitaOpened at output operation
Resistenza ambientale: Resistenza alle vibrazioni10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
Uscita di giudizio (HI, GO, LO): protezione da cortocircuitoIncorporated

Descrizione del prodotto

High performance analog laser high resolution controller, HL-C2 series, RS232 port, analog output ±5V/ 4 - 20mA, PNP digital output
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente