| Parametro | Valore |
|---|---|
| When communication unitis connected | |
| Articolo | Specifications |
| Cavo | 0.15 mm27-core composite cable, 2 m6.562 ftlong |
| Dettagli | Slave unit / High performance type |
| Prodotto | Controller |
| Materiale | Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal |
| Peso netto | 140 g approx. |
| Numero di parte | HG-TC111-P |
| Da 1 a 7 unità | 1 to 6 units |
| Nome del prodotto | Thru-beam Type Digital Displacement Sensor HG-T |
| da 8 a 15 unità | 7 to 14 units |
| Intervallo di visualizzazione | -199.999 to 199.999 mm-7.874 to 7.874 in |
| Frequenza di campionamento | 1 ms (standard sampling) / 0.5 ms (high-speed sampling) |
| Numero di prodotto | HG-TC111-P |
| Tensione di alimentazione | 24 V DC ±10 %, including ripple 0.5 V (P-P) |
| Grado di inquinamento | 2 |
| Risoluzione dello schermo | 1 μm0.039 mil |
| Altitudine operativa | 2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| Consumo attuale | 100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output. |
| Conformità normativa | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Testa del sensore applicabile | HG-T1010、HG-T1110 |
| Commutazione dell'ingresso esterno | Input 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop". |
| Commutazione dell'uscita esterna | Output 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2. |
| Conteggio medio (tempo di risposta) | 1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| Numero di unità slave collegate | Maximum sink current and sourcecurrent of control output |
| Resistenza ambientale: Protezione | IP40(IEC) |
| Uscita analogica: Uscita di corrente analogica | •Current output range: 4 to 20 mA/F.S. (default value)•Linearity: ±0.25 % F.S.•Output when alarm occurs: 0 mA•Load impedance: 250 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output. |
| Uscita analogica: Uscita di tensione analogica | •Voltage output range: 1 to 5 V/F.S. (default value)•Linearity: ±0.05 % F.S.•Output when alarm occurs: 5.2 V•Output impedance: 100 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output. |
| Ingresso esterno (Ingresso 1, Ingresso 2, Ingresso 3) | Non-contact input or NPN open-collector transistor•Input conditionsInvalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC•Input impedance: 10 kΩ approx.Non-contact input or PNP open-collector transistor•Input conditionsInvalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC•Input impedance: 10 kΩ approx. |
| Numero massimo di controller collegabili | Up to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
| Resistenza ambientale: Umidità ambientale | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Resistenza ambientale: Resistenza agli urti | 98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each |
| Uscita di controllo (Uscita 1, Uscita 2, Uscita 3) | NPN open-collector transistor•Maximum sink current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and 0 V)•Residual voltage: 1.5 V or less (at 50 mA sink current)•Leakage current: 0.1 mA or lessPNP open-collector transistor•Maximum source current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and +V)•Residual voltage: 1.5 V or less (at 50 mA source current)•Leakage current: 0.1 mA or less(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| Resistenza ambientale: Temperatura ambiente | -10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| Resistenza ambientale: Resistenza alle vibrazioni | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each |
| Resistenza ambientale: Resistenza di isolamento | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Resistenza ambientale: resistenza alla tensione | 1,000 V AC for one minute between all supply terminals connected together and enclosure |
| Input esterno (Input 1, Input 2, Input 3): Tempo di input | • Trigger input: 2 ms or more (ON)• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| Uscita di controllo (Uscita 1, Uscita 2, Uscita 3): Uscita di allarme | Open when alarm occurs |
| Uscita di controllo (Uscita 1, Uscita 2, Uscita 3): Uscita di giudizio | N.O. / N.C. switching type |
| Uscita di controllo (Uscita 1, Uscita 2, Uscita 3): protezione da cortocircuito | Incorporated (automatic reset type) |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo