Specifiche chiave
:When communication unitis connected
Articolo:Specifications
Cavo:0.15 mm27-core composite cable, 2 m6.562 ftlong
Dettagli:Slave unit / High performance type
Informazioni fornitore
PANASONIC
PANASONIC
Prodotti: 4316
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
When communication unitis connected
ArticoloSpecifications
Cavo0.15 mm27-core composite cable, 2 m6.562 ftlong
DettagliSlave unit / High performance type
ProdottoController
MaterialeCase: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Peso netto140 g approx.
Numero di parteHG-TC111-P
Da 1 a 7 unità1 to 6 units
Nome del prodottoThru-beam Type Digital Displacement Sensor HG-T
da 8 a 15 unità7 to 14 units
Intervallo di visualizzazione-199.999 to 199.999 mm-7.874 to 7.874 in
Frequenza di campionamento1 ms (standard sampling) / 0.5 ms (high-speed sampling)
Numero di prodottoHG-TC111-P
Tensione di alimentazione24 V DC ±10 %, including ripple 0.5 V (P-P)
Grado di inquinamento2
Risoluzione dello schermo1 μm0.039 mil
Altitudine operativa2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Consumo attuale100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output.
Conformità normativaCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Testa del sensore applicabileHG-T1010、HG-T1110
Commutazione dell'ingresso esternoInput 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop".
Commutazione dell'uscita esternaOutput 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2.
Conteggio medio (tempo di risposta)1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Numero di unità slave collegateMaximum sink current and sourcecurrent of control output
Resistenza ambientale: ProtezioneIP40(IEC)
Uscita analogica: Uscita di corrente analogica•Current output range: 4 to 20 mA/F.S. (default value)•Linearity: ±0.25 % F.S.•Output when alarm occurs: 0 mA•Load impedance: 250 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Uscita analogica: Uscita di tensione analogica•Voltage output range: 1 to 5 V/F.S. (default value)•Linearity: ±0.05 % F.S.•Output when alarm occurs: 5.2 V•Output impedance: 100 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Ingresso esterno (Ingresso 1, Ingresso 2, Ingresso 3)Non-contact input or NPN open-collector transistor•Input conditionsInvalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC•Input impedance: 10 kΩ approx.Non-contact input or PNP open-collector transistor•Input conditionsInvalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC•Input impedance: 10 kΩ approx.
Numero massimo di controller collegabiliUp to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
Resistenza ambientale: Umidità ambientale35 to 85 % RH, Storage: 35 to 85 % RH
Resistenza ambientale: Resistenza agli urti98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each
Uscita di controllo (Uscita 1, Uscita 2, Uscita 3)NPN open-collector transistor•Maximum sink current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and 0 V)•Residual voltage: 1.5 V or less (at 50 mA sink current)•Leakage current: 0.1 mA or lessPNP open-collector transistor•Maximum source current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and +V)•Residual voltage: 1.5 V or less (at 50 mA source current)•Leakage current: 0.1 mA or less(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Resistenza ambientale: Temperatura ambiente-10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Resistenza ambientale: Resistenza alle vibrazioni10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each
Resistenza ambientale: Resistenza di isolamento20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Resistenza ambientale: resistenza alla tensione1,000 V AC for one minute between all supply terminals connected together and enclosure
Input esterno (Input 1, Input 2, Input 3): Tempo di input• Trigger input: 2 ms or more (ON)• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Uscita di controllo (Uscita 1, Uscita 2, Uscita 3): Uscita di allarmeOpen when alarm occurs
Uscita di controllo (Uscita 1, Uscita 2, Uscita 3): Uscita di giudizioN.O. / N.C. switching type
Uscita di controllo (Uscita 1, Uscita 2, Uscita 3): protezione da cortocircuitoIncorporated (automatic reset type)

Descrizione del prodotto

HG-T Laser Displacement Sensor. High Functionality Slave Controller, PNP Output
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo

Top