


| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 0.2 m0.656 ft4-core shielded cable with round connectors |
| Dettagli | Measurement width 10 mm0.394 in/ Slim type |
| Prodotto | Sensor heads |
| Materiale | Case: Die-cast aluminum, Light emitting and light receiving surfaces: Glass |
| Linearità | ±0.12 % F.S. (Installation distance: 20 mm0.787 in)±0.28 % F.S. (Installation distance: 100 mm3.937 in)(Note)Indicates an error with the ideal straight line of digital measured values. |
| Peso netto | Emitter: 30 g approx., Receiver: 25 g approx. |
| Numero di parte | HG-T1110 |
| Fonte di luce | Red semiconductor laser: Class 1 [IEC / EN / JIS / GB / KS / FDA](Note)This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3. |
| Nome del prodotto | Thru-beam Type Digital Displacement Sensor HG-T |
| Ripetibilità | 1 μm0.039 mil(Installation distance: 20 mm0.787 in)2.5 μm0.098 mil(Installation distance: 100 mm3.937 in)5 μm0.197 mil(Installation distance: 500 mm19.685 in)(Note)This is the P-P value of digital measurement value with half shading at the middle position of the installation distance. |
| Numero di prodotto | HG-T1110 |
| Metodo di messa a terra | Capacitor grounding |
| Grado di inquinamento | 2 |
| Larghezza di misura | 10 mm0.394 in |
| Altitudine operativa | 2,000 m6,561.68 ftor less(Note)Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| Oggetto di rilevamento minimo | ø0.5 mmø0.020 in(Installation distance: 500 mm19.685 in)(Note)When the light is blocked at the center position of 500 mm19.685 ininstallation distance. |
| Indicatore di funzionamento | Emitter : Laser radiation indicator (Green)Receiver : Judgment output indicator (Orange / Green) |
| Controller applicabile | HG-TC101 (-P), HG-TC111 (-P), HG-TC113 |
| Distanza di installazione | 0 to 500 mm0 to 19.685 in |
| Conformità normativa | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA regulations |
| Metodo di rilevamento della posizione | CMOS-based |
| Caratteristiche di temperatura | ±0.03 % F.S./℃(Note)When the light is half-blocked at the center position of 100 mm3.937 ininstallation distance. |
| Resistenza ambientale: Protezione | IP67 (IEC) (Excluding connectors) |
| Resistenza ambientale: Umidità ambientale | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Resistenza ambientale: Resistenza agli urti | 196 m/s2acceleration in X, Y and Z directions three times each |
| Resistenza ambientale: Illuminazione ambientale | Incandescent light: 5,000 ℓx or less at the light-receiving face(Note)When the sampling cycle of the controller is set to "standard sampling". |
| Resistenza ambientale: Temperatura ambiente | -10 to +45 ℃+14 to +113 ℉(No dew condensation or icing allowed), Storage: -20 to +60 ℃-4 to +140 ℉ |
| Resistenza ambientale: Resistenza alle vibrazioni | 10 to 55 Hz frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| Resistenza ambientale: Resistenza di isolamento | 20 MΩ or higher, using 250 V DC megger (between all terminals and case) |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo