| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 0.2 mm26-core cabtyre cable, 2 m6.562 ftlong |
| Peso | Net weight: 60 g approx.Gross weight: 100 g approx. |
| Dettagli | Cable type |
| Prodotto | Digital Fiber Sensor |
| Materiale | Enclosure, Case cover: PolycarbonateSwitch: Polyacetal |
| Accessorio | FX-MB1 (Amplifier protection seal): 1 set |
| Protezione | IP40 (IEC) |
| Numero di parte | FX-505P-C2 |
| Nome del prodotto | Digital Fiber Sensor FX-500 Ver.2 |
| Uscita analogica | Output current: 4 to 20 mA approx. [H-SP, FAST STD: At 0 to 4,000 digits, LONG: At 0 to 8,000 digits (Note) ]Response time: 2 ms or lessZero point: Within 4 mA plus or minus 1 % F.S.Span: Within 16 mA plus or minus 5 % F.S.Linearity: Within plus or minus 3 % F.S.Load resistance: 0 to 250 Ohm(Note) If display adjustment was conducted, it is not in this range. |
| Tempo di risposta | H-SP: 25 micro s or lessFAST: 60 micro s or lessSTD: 250 micro s or lessLONG: 2 ms or lessU-LG: 4 ms or lessHYPR: 24 ms or less, selectable |
| Input esterno | PNP non-contact input- Signal conditionHigh: +4 V to +V DC (at 3 mA sink current)Low: 0 to +0.6 V DC or Open- Input impedance: 10 kOhm approx. |
| Numero di prodotto | FX-505P-C2 |
| Tensione di alimentazione | 12 to 24 V DC+10-15 % Ripple P-P 10 % or less |
| Funzione timer | Incorporated with variable OFF-delay / ON-delay /One-shot / ON-delay - OFF-delay / ON-delay - One-shot timer, switchable either effective or ineffectiveIncorporated with variable OFF-delay / ON-delay /One-shot timer, switchable either effective or ineffective |
| Prolunga del cavo | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (however, supply voltage 12 V DC or more) |
| Varie impostazioni | Hysteresis setting / Shift amount setting / Emission power setting / Display turning setting / ECO setting / Data bank loading saving setting / Copying setting / Code setting / Reset setting / Logical calculation setting / Threshold value tracking setting, etc. |
| Consumo energetico | Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage, excluding analog output)ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage, excluding analog output) |
| Uscita 1, Uscita 2 | PNP open-collector transistor- Maximum source current: 50 mA (Note 1)- Applied voltage: 30 V DC or less (between output and +V)- Residual voltage: 2 V or less (Note 2) (at maximum source current)(Note 1) 50 mA max. if 5 or more standard types are connected together.(Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type) |
| Temperatura ambiente | -10 to +55 ℉+14 to +131 ℉[If 4 to 7 units are mounted in cascade: -10 to +50 ℉+14 to +122 ℉or if 8 to 12 units are mounted in cascade: -10 to +45 ℉+14 to +113 ℉] (No dew condensation or icing allowed), Storage: -20 to +70 ℉-4 to +158 ℉ |
| Impostazione della sensibilità | 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment |
| Funzione timer: periodo del timer | Timer range ''ms'': 0.5 ms approx., 1 to 9,999 ms approx., 1 ms approx.Timer range ''sec.'': 0.5 s approx., 1 to 32 s approx., 1 s approx.Timer range ''1/10 ms'': 0.05 ms approx., 0.1 to 999.9 ms approx., 0.1 ms approx.each output is set individually |
| Elemento emittente (modulato) | Red LED (Peak emission wavelength: 643 nm0.025 mil) |
| Conformità alla direttiva sulla marcatura CE | EMC Directive, RoHS Directive |
| Funzione di impostazione della quantità di emissione | Incorporated, 3 levels (each level 25 to 100 %) + Auto setting [1 level (25 to 100 %) when using H-SP mode] |
| Funzione di prevenzione delle interferenze | Incorporated (Note) , selectable either automatic interference prevention or different frequency(Note) Number of sensor heads which is possible to be mounted closely in auto interference prevention function depends on response time as shown in table below.Number of sensor heads which is possible to be mounted closely in different frequency Interference prevention function is up to 3 units.- Number of sensor heads mountable closely (Unit: set)Response time: IP-1H-SP: 0FAST: 2STD: 4LONG: 8U-LG: 8HYPR: 12 |
| Uscita 1, Uscita 2: Punti di uscita | 2 points |
| Possibile funzione di input esterno | Emission halt / Teaching (Full-auto, Limit, 2-point) / Logic operation setting / Copy lock / Display adjustment / Data bank load / Data bank save, selectable |
| Uscita 1, Uscita 2: Funzionamento dell'uscita | Switchable either Light-ON or Dark-ON by L/D mode |
| Intervallo di visualizzazione dell'intensità della luce incidente | H-SP / FAST / STD: 0 to 4,000LONG: 0 to 8,000U-LG / HYPR: 0 to 9,999 |
| Ingresso esterno (commutabile con Uscita 2) | - |
| Uscita 1, Uscita 2: Protezione da cortocircuito | Incorporated |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo