| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Produzione | NPN open-collector transistor・Maximum sink current: 100 mA・Applied voltage: 30 V DC or less (between output and 0 V)・Residual voltage: 1.5 V or less (at 100 mA sink current)0.4 V or less (at 16 mA sink current) |
| Peso | Emitter: 45 g approx., Receiver: 50 g approx. |
| Dettagli | NPN output |
| Prodotto | Water Detection Sensor |
| Materiale | Polycarbonate |
| Accessorio | Adjusting screwdriver: 1 pc. |
| Dimensioni | W12 x H31 x D20 mmW0.472 x H1.221 x D0.787 in |
| Protezione | IP67 (IEC) |
| Numero di parte | EZ-11 |
| Nome del prodotto | Water Detection Sensor EZ-10 |
| Tempo di risposta | 12 ms or less |
| Campo di rilevamento | 5 m16.404 ft(without container or pipe)(Note):The sensing range shortens depending on the thickness, material, color, etc., of the container or pipe. |
| Numero di prodotto | EZ-11 |
| Oggetto di rilevamento | ø12 mmø0.472 mmor more liquid which contains water, or opaque object(Note):If there are two slit masks on both sides, the size of those slit masks represents the min. sensing object. |
| Tensione di alimentazione | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
| Umidità ambientale | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Elemento emittente | Infrared LED (modulated) |
| Resistenza agli urti | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Illuminazione ambientale | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Temperatura ambiente | 0 to +55 ℃+32 to +131℉(No dew condensation allowed), Storage: -30 to +70 ℃-22 to +158℉ |
| Consumo attuale | Emitter: 25 mA or less, Receiver: 25 mA or less |
| Regolatore di sensibilità | Continuously variable adjuster |
| Resistenza alle vibrazioni | 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude (20 G max.) in X, Y and Z directions for two hours each |
| Resistenza di isolamento | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Output:Operazione di output | Switchable either Light-ON or Dark-ON |
| Resistenza alla tensione | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Output:Categoria di utilizzo | DC-12 or DC-13 |
| Conformità alla direttiva sulla marcatura CE | EMC Directive, RoHS Directive |
| Uscita: protezione da cortocircuito | Switchable either Light-ON or Dark-ON |
Specifiche tecniche e dati di prestazione