| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 0.15 mm24-core cabtyre cable, 2 m6.562 ftlong |
| Produzione | PNP open-collector transistor- Maximum source current: 50 mA |
| Peso | Net weight: 45 g approxGross weight: 60 g approx |
| Dettagli | Convergent reflective type |
| Prodotto | Amplifier Built-in Ultra-compact Laser Sensor |
| Materiale | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessorio | MS-EXL2-3 (Mounting plate): 1 pc. |
| Isteresi | 20 % or less of operation distance |
| Protezione | IP67(IEC) |
| Numero di parte | EX-L262-P |
| Nome del prodotto | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Ripetibilità | Perpendicular to sensing axis: 0.2 mm0.0080 inor less |
| Tempo di risposta | 0.5 ms or less |
| Campo di rilevamento | 20 to 70 mm0.787 to 2.756 in(Convergent point: 22 mm0.866 in)(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Numero di prodotto | EX-L262-P |
| Oggetto di rilevamento | Opaque, translucent or transparent object(Note)Make sure to confirm detection with an actual sensor before use. |
| Tensione di alimentazione | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Prolunga del cavo | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable |
| Umidità ambientale | 35 to 85%RH , Storage: 35 to 85%RH |
| Elemento emittente | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS)(Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).)(Maximum output: 1.3 mW, Peak emission wavelength: 655 nm0.026 mil) |
| Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Consumo attuale | 15 mA or less |
| Regolatore di sensibilità | Continuously variable adjuster |
| Conformità normativa | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Output:Operazione di output | Light-ON / Dark-ON selectable by the output operation switching input |
| Dimensioni del punto di emissione (tipico) | Approx. 5 × 1 mm0.197 × 0.039 in(vertical x horizontal)(at a sensing distance of 50 mm) |
| Uscita: protezione da cortocircuito | Incorporated (short-circuit protection / inverse polarity protection) |
| Oggetto minimo di rilevamento (tipico) | - |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo