| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Produzione | NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current) |
| Dettagli | Chemical-resistant |
| Prodotto | Leak Detection Sensor |
| Materiale | Enclosure: PFA |
| Protezione | IP67 (IEC) |
| Numero di parte | EX-F62 |
| Nome del prodotto | Leak Detection Sensor EX-F70/EX-F60 |
| Tempo di risposta | 50 ms or less |
| Numero di prodotto | EX-F62 |
| Oggetto di rilevamento | Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.Note : Highly viscous liquid may not be detected stably.Note : The agents mentioned above are examples. For details, please contact our office.Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. |
| Tensione di alimentazione | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
| Prolunga del cavo | Extension up to total 50 m164.042 ft |
| Indicatore di GUASTO | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) |
| Umidità ambientale | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Elemento emittente | Infrared LED (non-modulated) |
| Indicatore NORMALE | Green LED (lights up when the sensor is mounted properly) |
| Illuminazione ambientale | Incandescent light: 1,000 ℓx or less at the light-receiving face |
| Temperatura ambiente | -10 to +60 ℃+14 to +140 ℉(No dew condensation or icing allowed), Storage: -20 to +70 ℃- 4 to +158 ℉Note : Liquid being detected should also be kept within the rated ambient temperature range. |
| Consumo attuale | 15 mA or less |
| Output:Operazione di output | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF |
| Uscita: protezione da cortocircuito | Incorporated |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo