| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 0.1 mm23-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long |
| Produzione | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 30 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) |
| Peso | Net weight (each emitter and receiver): 20 g approxGross weight: 50 g approx |
| Dettagli | Thru-beam・Narrow Beam [Front sensing] |
| Prodotto | Ultra-slim Photoelectric Sensor |
| Materiale | Enclosure: PolyarylateLens: Polyarylate |
| Accessorio | Mounting screws: 1 set |
| Isteresi | - |
| Protezione | IP67 (IEC) |
| Numero di parte | EX-13SB-PN |
| Nome del prodotto | Amplifier built-in Ultra-slim Photoelectric Sensor EX-10S |
| Certificazione | UL certification |
| Tempo di risposta | 0.5 ms or less |
| Campo di rilevamento | 500 mm 19.685 in |
| Numero di prodotto | EX-13SB-PN |
| Tensione di alimentazione | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Prolunga del cavo | Extension up to total 50 m164 ftis possible with 0.3 mm2, or more, cable (emitter and receiver).(Note) : For safety applications, do not exceed 30 m98.425 ft. |
| Umidità ambientale | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Elemento emittente | Red LED (Peak emission wavelength: 680 nm 0.027 mil, modulated) |
| Grado di inquinamento | 3 (Industrial environment) |
| Resistenza agli urti | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions for three times each |
| Illuminazione ambientale | Incandescent light: 3,000 lx at the light-receiving face |
| Temperatura ambiente | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit |
| Consumo attuale | Emitter: 10 mA or lessReceiver: 10 mA or less |
| Oggetto di rilevamento minimo | dia. 1.0 mm dia. 0.039 in opaque object (Completely beam interrupted object)(Note) : The min. sensing objects are specified in case the emitter / reciever sensing range is to set the maximum. |
| Indicatore di funzionamento | Orange LED (lights up when the output is ON) |
| Indicatore di stabilità | Green LED (lights up under stable light received condition or stable dark condition) |
| Resistenza alle vibrazioni | 10 to 500 Hz frequency, 3 mm 0.118 in amplitude (20 G max.) in X, Y and Z directions for two hours each |
| Resistenza di isolamento | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Conformità normativa | ・EMC Directive : EN 60947-5-2・RoHS Directive・ISO 13849-1 (Category 1, PLc) (Note)(Note) : Conformed from December 2021 production. |
| Indicatore del raggio incidente | - |
| Resistenza alla tensione | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Output:Categoria di utilizzo | DC-12 or DC-13 |
| Uscita: protezione da cortocircuito | Incorporated |
| Ripetibilità (perpendicolare all'asse di rilevamento) | 0.05 mm 0.002 in or less |