| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 0.2 mm24-core cabtyre cable, 2 m6.562 ftlong |
| Produzione | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) |
| Peso | Net weight: 55 g approx.Gross weight: 65 g approx. |
| Dettagli | Adjustable range reflective |
| Prodotto | Compact Photoelectric Sensor |
| Materiale | Enclosure: PBT (Polybutylene terephthalate)Front cover: PolycarbonateIndicator cover: Polycarbonate |
| Isteresi | 2 % or less of operation distance(with white non-glossy paper) |
| Protezione | IP67 (IEC) |
| Numero di parte | CX-444 |
| Nome del prodotto | Compact Photoelectric Sensor CX-400 Ver.2 |
| Modalità di rilevamento | BGS / FGS functions switchable with wiring of sensing mode selection input |
| Ripetibilità | Along sensing axis: 1 mm0.039 inor less, Perpendicular to sensing axis: 0.2 mm0.008 inor less (with white non-glossy paper) |
| Tempo di risposta | 1 ms or less |
| Diametro del punto | Ø9 mmØ0.354 inapprox.(at 100 mm 3.937 in distance) |
| Numero di prodotto | CX-444 |
| Tensione di alimentazione | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Prolunga del cavo | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Gamma regolabile | 20 to 100 mm0.787 to 3.937 in(Note) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can detect an object 2 mm0.079 in[CX-444(-P): 15 mm0.591 in, CX-442(-P): 20 mm0.787 in], or more, away. |
| Umidità ambientale | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Resistenza agli urti | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Regolatore di distanza | 5-turn mechanical adjuster |
| Illuminazione ambientale | Incandescent light: 3,000 lx or less at the light-receiving face |
| Temperatura ambiente | - 25 to +55℃-13 to +131℃ ℉(No dew condensation or icing allowed ), Storage: -30 to +70℃-22 to +158℃ ℉ |
| Consumo attuale | 20 mA or less |
| Indicatore di funzionamento | Orange LED (lights up when the output is ON) |
| Indicatore di stabilità | Green LED(lights up under stable operating condition) |
| Resistenza alle vibrazioni | 10 to 500 Hz frequency, 3 mm0.118 inamplitude in X, Y and Z directions for two hours each |
| Resistenza di isolamento | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Output:Operazione di output | Switchable either Detection-ON or Detection-OFF |
| Resistenza alla tensione | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Elemento emittente (modulato) | Red LED |
| Conformità alla direttiva sulla marcatura CE | EMC Directive, RoHS Directive |
| Uscita: protezione da cortocircuito | Incorporated |
| Funzione di prevenzione automatica delle interferenze | Incorporated(Note) Note that detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. |
| Campo di rilevamento (con carta bianca non lucida) | 15 to 100 mm0.591 to 3.937 in |
| Elemento emittente (modulato): lunghezza d'onda di emissione di picco | 650 nm0.026 mil |