Orario di servizio: Lunedì a Venerdì 9:00-18:00
SFC14EX - SFC14EX SF-C14EX PANASONIC Safety sensor accessory
Disponibile Prodotto più richiesto

SFC14EX

SFC14EX SF-C14EX PANASONIC Safety sensor accessory

$0.00USD
3551 in magazzino
Specifiche chiave
Articolo:Specifications
PFHD:1.66 × 10-10(Note:Probability of dangerous failure per hour)
MTTFD:100 years or more(Note:Mean time to dangerous failure (in years))
Peso:Net weight: 250 g approx.
Informazioni fornitore
PANASONIC
PANASONIC
Prodotti: 4316
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
ArticoloSpecifications
PFHD1.66 × 10-10(Note:Probability of dangerous failure per hour)
MTTFD100 years or more(Note:Mean time to dangerous failure (in years))
PesoNet weight: 250 g approx.
DettagliApplicantion expansion unit for the SF4B series
ProdottoExclusive Control Unit for Safety Light Curtain
MaterialeEnclosure: ABS
Numero di parteSF-C14EX
Nome del prodottoExclusive Control Unit for Safety Light Curtain SF-C10
Tensione di alimentazione24 V DC plus or minus 10 % Ripple P-P 10 % or less
Numero di prodottoSF-C14EX
Umidità ambientale30 to 85 % RH, Storage: 30 to 95 % RH
Categoria di controlloISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Resistenza agli urti30 G acceleration in X, Y and Z directions three times each
Uscita lampada di silenziamentoApplicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit)
Temperatura ambiente-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉
Terminale di collegamentoDetachable spring-cage terminal
Consumo attuale0.2 A or less (Excluding Safety light curtain and other external connecting device)
Resistenza alle vibrazioni10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each
Resistenza di isolamento20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Norme applicabili: GiapponeJIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe)
Conformità alla direttiva sulla marcatura CEMachinery Directive, EMC Directive, RoHS Directive
Norme applicabili: Europa (UE)EN 55011, EN ISO 13849-1 (Category 4, PLe)
Barriere fotoelettriche di sicurezza collegabiliSF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.)
Norme applicabili: Nord AmericaANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Uscita lampada di silenziamento: circuito di protezioneIncorporated
Norme applicabili: Norma internazionaleIEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe)
Resistenza ambientale: Grado di protezioneEnclosure: IP40Terminal: IP20
Resistenza ambientale: tensione di rigidità dielettrica1,000 V AC for one min. between all supply terminals connected together and enclosure
Uscite di sicurezza (Uscita di sicurezza 1, Uscita di sicurezza 2, Uscita di sicurezza 3)PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current)
Uscite di sicurezza (Uscita di sicurezza 1, Uscita di sicurezza 2, Uscita di sicurezza 3): Tempo di rispostaOFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3.
Uscite ausiliarie (Uscita ausiliaria 1, Uscita ausiliaria 2, Uscita ausiliaria 3, Uscita ausiliaria 4)PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current)
Uscite di sicurezza (Uscita di sicurezza 1, Uscita di sicurezza 2, Uscita di sicurezza 3): Modalità di funzionamento (Funzionamento dell'uscita)Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid
Uscite di sicurezza (uscita di sicurezza 1, uscita di sicurezza 2, uscita di sicurezza 3): circuito di protezione (protezione da cortocircuito)Incorporated
Uscite ausiliarie (Uscita ausiliaria 1, Uscita ausiliaria 2, Uscita ausiliaria 3, Uscita ausiliaria 4): Modalità di funzionamento (Funzionamento dell'uscita)Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.)
Uscite ausiliarie (uscita ausiliaria 1, uscita ausiliaria 2, uscita ausiliaria 3, uscita ausiliaria 4): circuito di protezione (protezione da cortocircuito)Incorporated

Descrizione del prodotto

SF-C14EX_Exclusive Control Unit for Safety Light Curtain_Exclusive Control Unit for Safety Light Curtain SF-C10_Applicantion expansion unit for the SF4B series