Specifiche chiave
Articolo:Specifications
PFHD:2.78×10-9
MTTFD:426 years or more
Osservazione:Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years).
Informazioni fornitore
PANASONIC
PANASONIC
Prodotti: 4316
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
ArticoloSpecifications
PFHD2.78×10-9
MTTFD426 years or more
OsservazioneWhere measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years).
DettagliMin. sensing object ø25 mmø0.984 in(20 mm0.787 inbeam pitch)
ProdottoSafety Light Curtain [Type 4 PLe SIL3]
MaterialeEnclosure : Aluminum, Detection surface : Polycarbonate resin and stainless steel (SUS304), Upper cap / lower cap : Nylon
AccessoriSF4B-TR25 (test rod) : 1 pc.
Numero di parteSF4D-H56-01
Nome del prodottoCompact & Robust Safety Light Curtain [Type 4 PLe SIL3] SF4D
Stato di sicurezzaControl output (OSSD 1 / 2) OFF state
Tensione di alimentazione24 V DC+20-30 %Ripple P-P 10 % or less (excluding voltage drop due to cable)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline.
Numero di prodottoSF4D-H56-01
Tipo di sottosistemaType B (IEC 61508-2)
Prolunga del cavoTotal length of emitter / receiver can be extended up to 70 m229.659 fteach using optional mating cable (including the lengthof series mating cables)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline.
Funzione di disattivazione audioIncorporated (12-core cable)
Gamma operativaShort mode : 0.2 to 9 m0.656 to 29.528 ftLong mode : 0.8 to 15 m2.625 to 49.213 ft(selectable by DIP switch)(Note): The operating range is the possible setting distance between the emitter and the receiver.
Umidità ambientale30 to 85 % RH, Storage : 30 to 95 % RH
Elemento emittenteInfrared LED (peak emission wavelength : 850 nm0.0335 mil)
Grado di inquinamento3
Resistenza agli urti300 m/s2acceleration (30 G approx.) in X, Y, and Z directions three times eachMalfunction resistance 100 m/s2acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each
Metodo di collegamentoBy connector
Funzione di overrideIncorporated (12-core cable)
Altezza di protezione1,110 mm43.701 in(Note): When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height.
Funzione di interbloccoIncorporated [Manual reset / auto reset (selectable by wiring)] (8-core cable or 12-core cable)
Altitudine operativa2,000 m6,561.68 ftor less(Note): Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
Funzioni opzionaliOptional functions cannot be used when SF4D-□-01 is used.
Illuminazione ambientaleIncandescent light : 5,000 ℓx or less at the light-receiving surface
Temperatura ambiente-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage : -25 to +60 ℃-13 to +140 ℉
Consumo attualeEmitter : 120 mA or lessReceiver : 140 mA or less
Oggetto di rilevamento minimoø25 mmø0.984 inopaque object(Note): When the floating blanking function is used, the size of the minimum sensing object varies. For the detail, refer to the section on Safety distance.
Funzione di risparmio energeticoIncorporated
Funzione di input di provaIncorporated
Numero di canali del fascio56
Resistenza alle vibrazioni10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions for two hours eachMalfunction resistance 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions twenty times each
Tempo di risposta al guastoWithin response time (OFF response)
Resistenza di isolamento20 MΩ, or more, with 500 V DC megger, between all supply terminals connected together and enclosure
Metodo di sincronizzazioneLine synchronization / optical synchronization (selectable by DIP switch)
Angolo di apertura effettivo±2.5° or less at a sensing range of 3 m9.843 ftor longer (based on IEC 61496-2)
Funzione di sbloccoIncorporated
T1 (intervallo di prova di prova)20 years
Norme applicabili: GiapponeJIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
SFF (frazione di guasti sicuri)99%
Funzione indicatore di applicazioneIncorporated (only the receiver lights up when optical synchronization is used)
HFT (tolleranza ai guasti hardware)1
Norme applicabili: Cina (GB)GB/T 4584
Conformità alla direttiva sulla marcatura CEMachinery Directive, EMC Directive, RoHS Directive
Norme applicabili: Europa (UE)EN 61496-1/2 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 55011, EN 61000-6-2, EN 50178
Uscite di controllo (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 350 mA・Applied voltage : Same as supply voltage(between control output and +V)・Residual voltage : 2 V or less (source current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less<NPN output selected>・Maximum sink current : 350 mA・Applied voltage : Same as supply voltage(between control output and 0 V)・Residual voltage : 2 V or less (sink current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less
Funzione di prevenzione delle interferenze<Not connected in series/parallel>・Line synchronization : 2 units or less (auto)・Optical synchronization : 2 units or less (selectable by DIP switch)<Connected in series/parallel>・Series connection : 5 units or less (total number of beam channels 256 or less)・Parallel connection : 3 units or less (total number of beam channels 192 or less)(Note)・Series / parallel connection mixed : 5 units or less (total number of beam channels 144 or less)(Note)(Note): Note that the setting cannot be changed when SF4D-□-01 is used.
Norme applicabili: Nord AmericaANSI/UL 61496-1/2 (Type 4),CAN/CSA C22.2 No.14, CAN/CSA E61496-1/2
Funzione di monitoraggio del dispositivo esternoIncorporated (8-core cable or 12-core cable)
Peso (totale dell'emettitore e del ricevitore)2,800g approx.
Uscita ausiliaria (AUX) (uscita non di sicurezza)PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and +V)・Residual voltage : 2 V or less (source current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)<NPN output selected>・Maximum sink current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and 0 V)・Residual voltage : 2 V or less (sink current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)
Norme applicabili: Norma internazionaleIEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
Uscita di controllo (OSSD 1, OSSD 2): tempo di rispostaOFF response : 10 ms or less (Not connected in series / parallel), 18 ms or less (Connected in series / parallel)(Note 1)ON response : 50 ms or less (Note 2)(Note 3)(Note 1): For response times by number of beams, refer to the Control output (OSSD 1, OSSD 2) OFF response times.(Note 2): Because the control output (OSSD 1, OSSD 2) must be OFF for at least 80 ms, the ON response will be delayed more than 50 ms when the light blocked time is less than 30 ms.(Note 3): When optical synchronization is selected, if the beam axes of both the top end and bottom end are blocked, the ON response speed decreases by as much as 1 sec.
Resistenza ambientale: Grado di protezioneIP67, IP65 (IEC), NEMA Type 13 (NEMA 250)
Uscite di controllo (OSSD 1, OSSD 2): Modalità di funzionamentoON when all beams are received, OFF when one or more beams are blocked(Also OFF when internal sensor error or synchronization signal error occurs)(Note): Note that the setting cannot be changed when SF4D-□-01 is used.
Uscite di controllo (OSSD1, OSSD2): Circuito di protezioneIncorporated
Resistenza ambientale: tensione di rigidità dielettrica1,000 V AC for one minute, between all supply terminals connected together and enclosure
Uscita ausiliaria (AUX) (uscita non di sicurezza): tempo di rispostaOFF response : 60 ms or less, ON response : 60 ms or less
Uscita ausiliaria (AUX) (uscita non di sicurezza): modalità di funzionamentoControl output ON : OFF, Control output OFF : ON(Note): Note that the setting cannot be changed when SF4D-□-01 is used.
Uscita ausiliaria (AUX) (uscita non di sicurezza): circuito di protezioneIncorporated
Altezza di protezione: quando utilizzato come dispositivo di sicurezza per macchine da stampa cinesi o quando utilizzato per macchine da stampa giapponesi o macchine per la tranciatura della carta1,100 mm43.307 in(Note): When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height.

Descrizione del prodotto

SF4D-H56-01_Safety Light Curtain [Type 4 PLe SIL3]_Compact & Robust Safety Light Curtain [Type 4 PLe SIL3] SF4D_Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch)
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo

Top