| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| PFHD | 9.71 × 10-9 |
| MTTFD | 100 years or more |
| Dettagli | Min. sensing object ø27 mm ø1.063 in type (20 mm0.787 inbeam pitch) |
| Prodotto | Safety Light Curtain Type 2 |
| Materiale | Enclosure: AluminiumUpper and lower edges : Die-cast zine alloyInner case: Polycarbonate / Polyester resinCap: PBT |
| Passo del fascio | 20 mm0.787 in |
| Accessori | MS-SF2B-2(Intermediate supporting bracket):3 setsSF2B-TR27 (Test rod): 1 No. |
| Numero di parte | SF2B-H96-P |
| Nome del prodotto | Safety Light Curtain Type 2 SF2B Ver.2 |
| Tensione di alimentazione | 24 V DC plus or minus 15 % Ripple P-P 10 % or less |
| Tempo di risposta | OFF response: 15 ms or lessON response: 40 to 60 ms |
| Numero di prodotto | SF2B-H96-P |
| Prolunga del cavo | Extension up to total 30.5 m100.066 ftis possible for both emitter and receiver, with optional mating cables. |
| Gamma operativa | 0.2 to 13 m0.656 to 42.651 ft(0.2 to 5 m0.656 to 16.404 ftwhen using the SF2B-CB05-B adapter cable) |
| Umidità ambientale | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Elemento emittente | Infrared LED (Peak emission wavelength: 870 nm0.034 mil) |
| Resistenza agli urti | 300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Metodo di collegamento | Connector |
| Altezza di protezione | 1,912 mm75.275 in |
| Illuminazione ambientale | Incandescent light: 3,500 lx or less at the light-receiving face |
| Temperatura ambiente | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃-13 to +158 ℉ |
| Consumo attuale | Emitter: 80 mA or lessReceiver: 150 mA or less |
| Oggetto di rilevamento minimo | ø27 mm ø1.063 in opaque object |
| Numero di canali del fascio | 96 |
| Resistenza alle vibrazioni | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Resistenza di isolamento | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Uscita ausiliaria (Aux) | PNP open-collector transistor- Max. source current: 60 mA- Applied voltage: same as supply voltage [between the auxiliary output and +V]- Residual voltage: 2.5 V or less (sink current 60 mA)(when using 30.5 m100.066 ftlength cable)(Note) When using auxiliary output (AUX), the SF2B-CB05-B adapter cable (optional) cannot be used. |
| Funzione di arresto delle emissioni | Incorporated |
| Metodo di sincronizzazione | Cable synchronization (optical synchronization when using SF2B-CB05-B) |
| Angolo di apertura effettivo | plus or minus 5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / UL 61496-2)] |
| Norme applicabili: Giappone | JIS B 9704-1/2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL1) |
| Conformità alla direttiva sulla marcatura CE | Machinery Directive, EMC Directive, RoHS Directive |
| Norme applicabili: Europa (UE) | EN 61496-1 (Type 2), EN 55011 |
| Uscite di controllo (OSSD 1, OSSD 2) | PNP open-collector transistor- Max. source current: 200 mA- Applied voltage: same as supply voltage [between the control output (OSSD 1, OSSD 2) and +V]- Residual voltage: 2.5 V or less (sink current 200 mA) (when using 30.5 m100.066 ftlength cable) |
| Funzione di prevenzione delle interferenze | Incorporated- Series connection: 3 sets max. (Total 128 beam channels). (However, SF2B-Ax allows up to a total of 96 beam channels when two sets are connected, and up to 64 beam channels when three sets are connected). (Note 1)SF2B-Hx and SF2B-Ax can be used together. (Note 2)[When using SF2B-CB05-B (optical synchronization):- Series connection: 3 sets max. (Total 128 beam channels). (However, SF2B-Ax allows up to a total of 96 beam channels when two sets are connected, and up to 64 beam channels when three sets are connected). (Note 1)- Parallel connection: 2 sets max.- Series and parallel mixed connection: Series connection of 3 sets max. and parallel connection of 2 sets max. are simultaneously possible.SF2B-Hx and SF2B-Ax can be used together. (Note 2)](Note 1) The SF2B-H8-x and SF2B-A4-x cannot be connected in series.(Note 2) When making series connection mixing SF2B-Hx and SF2B-Ax, calculate by doubling the number of optical axes only for SF2B-Ax, and make the total number of optical axes fall below 128 axes.(e.g.) When making series connection with SF2B-H36 and SF2B-A44, the total number of optical axes will be 124 axes. The number of optical axes for SF2B-H36 + (number of optical axes for SF2B-A44 × 2) = total number of optical axes. 36 optical axes + (44 optical axes × 2) = 124 optical axes. |
| Norme applicabili: Nord America | UL 61496-1/2 (Type 2), UL 508, UL 1998 (Class 1), CSA C22.2 No.14, CSA C22.2 No.0.8, OSHA 1910.212 (Note), OSHA 1910.217 (C) (Note), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) Not compatible when using the bottom cap cable SF2B-CB05-A. |
| Funzione di monitoraggio del dispositivo esterno | Incorporated |
| Uscita ausiliaria (Aux): modalità di funzionamento | When using SF2B-CCBx or SF2B-CBx: OFF when OSSD ON, ON when OSSD OFFWhen using SF2B-CB05-A: ON during normal operation, OFF when there is a problem with emitter operation or emission is halted |
| Peso (totale dell'emettitore e del ricevitore) | 2,500 g approx. |
| Uscita ausiliaria (Aux): circuito di protezione | Incorporated |
| Norme applicabili: Norma internazionale | IEC 61496-1/2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL1) |
| Resistenza ambientale: Grado di protezione | IP65 (IEC) (*IP67 is later than Ver.2) |
| Uscite di controllo (OSSD 1, OSSD 2): Modalità di funzionamento | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) |
| Uscite di controllo (OSSD1, OSSD2): Circuito di protezione | Incorporated |
| Resistenza ambientale: tensione di rigidità dielettrica | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Specifiche tecniche e dati di prestazione