| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| manichino | dia. 150 mm dia. 5.906 in/0 to 4.0 m 0 to 13.123 ftdia. 70 mm dia. 2.756 in/0 to 4.0 m 0 to 13.123 ftdia. 50 mm dia. 1.969 in/0 to 2.8 m 0 to 9.186 ftdia. 40 mm dia. 1.575 in/0 to 2.2 m 0 to 7.218 ftdia. 30 mm dia. 1.181 in/0 to 1.6 m 0 to 5.249 ft |
| Peso | Net weight: 2.1 kg approxGross weight: 2.9 kg approx |
| Prodotto | Safety Laser Scanner Type 3 |
| Materiale | Main body: Die-cast aluminumScanner window: Thermoplastic resin |
| Accessori | SD3-PS (exclusive 15-pin connector): 1 pcSD3-RS232 (exclusive 9-pin connector): 1 pcMounting screws [M5 (length 20 mm 0.787 in) hexagon-socket-head bolt: 2 pcs M5 (length 16 mm 0.630 in) hexagon-socket-head bolt: 2 pcs., attached to SD3-PS]: 1 setSimplified instruction manual: 1 copyInstallation CD-ROM (includes detailed instruction manual data): 1 CD |
| Valore nominale del fusibile | 1.25 A semi-time-lag fuse |
| Numero di parte | SD3-A1 |
| Nome del prodotto | Safety Laser Scanner Type 3 SD3-A1 |
| Numero di prodotto | SD3-A1 |
| Umidità ambientale | Operation and storage: Max. 95 % RH (No dew condensation) |
| Temperatura ambiente | 0 to +50degrees +32 to +122 degrees Fahrenheit , Storage: -20 to +60degrees -4 to +140 degrees Fahrenheit |
| Consumo attuale | 300mA approx. (excluding external connection load) |
| Lunghezza massima del cavo | 15-pin plug: Max. 50 m 164.042 ft9-pin plug: Max. 10 m 32.808 ft (when using RS-232C) / Max. 50 m 164.042 ft (when using RS-422)(by using optional connection cable) (Note)(Note) Be careful that a voltage drop may occur depending on the cable length or cable's conductor cross-section area. |
| Norme applicabili: Giappone | JIS B 9704-1/3 (Type 3), JIS B 9705-1 (Category 3), JIS C 0508 (SIL2) |
| Norme applicabili: Europa (UE) | EN 61496-1 (Type 3), ISO 13849-1 (Category 3, PLd), EN 61508-1 to 7 (SIL2) |
| Uscite di controllo (OSSD 1, OSSD 2) | PNP open-collector transistor 2 outputs- Rated operating voltage: supply voltage (UB) - 3.2 V- Max. source current: 250 mA- Residual voltage: 3.2 V or less |
| Norme applicabili: Norma internazionale | IEC 61496-1/3 (Type 3), ISO 13849-1 (Category 3, PLd), IEC 61508-1 to 7 (SIL2), IEC 62061 (SIL2) |
| Uscita di controllo (OSSD 1, OSSD 2): tempo di risposta | Min. 80 ms (2 scans) to max. 640 ms (16 scans) switching method |
| Resistenza ambientale: Grado di protezione | IP65 |
| Uscite di controllo (OSSD 1, OSSD 2): Modalità di funzionamento | When no object enters into the detection zone: ONWhen an object enters: OFF |
| Uscite di controllo (OSSD 1, OSSD 2): Circuito di protezione | Incorporated |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo