Orario di servizio: Lunedì a Venerdì 9:00-18:00
S194156115 - S194156115 CARLO GAVAZZI Selected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or E..
Disponibile Prodotto più richiesto

S194156115

S194156115 CARLO GAVAZZI Selected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or E..

$0.00USD
4481 in magazzino
Informazioni fornitore
CARLO GAVAZZI
CARLO GAVAZZI
Prodotti: 10094
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Descrizione del prodotto

A94 Level Sensor Amplifier, Fill Control, 115 Vac Power Supply
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Dettagli tecnici

Conductive SensorsAmplifierTypes S 194, H 494 (Charging)• Control of CHARGING (swimming pools)• S 194 Output: 10 A SPDT relay• H 494 Output: 8 A DPDT relay• LED-indications: Power supply and relay ON• AC power supplyS 194H 494Product DescriptionOrdering KeyS 194 156 024Level controlrelay forcon- ductive liquids for swim- ming pool applications. The relay operates approx.10 safter the sensor is no long- er immersed in the water. Amplifier for A94-.. sensors.Housing Type/function OutputPower supplyType SelectionPlugOutput Supply: 24 VACSupply: 115 VACSupply: 230 VACCircular, 11 pin SPDT S 194 156 024 S 194 156 115 S 194 156 230Screw terminals DPDT H 494 166 024 H 494 166 115 H 494 166 230Output SpecificationsS194H494Output SPDT relay DPDT relayRated insulation voltage250 VAC (rms) 250 VAC (rms) (Cont./elec.) (Cont./elec., cont./cont.)Contact ratings (Ag-CdO) µ (micro gap) µ (micro gap)Resistive loadsAC 1 10 A/250 VAC (2500 VAC)8 A/250 VAC (200 VA) DC 1 1 A/250 VAC (250 W)0,4 A/250 VDC (100 W)or 10 A/25 VDC (250 W)4 A/25 VDC (100 W) Small inductive loadsAC 15 2.5 A/230 VAC 2.5 A/230 VACDC 13 5 A/24 VDC5 A/24 VDCMechanical life ≥ 5 x 107operations≥ 30 x 105operations Electricallife ≥105operations≥125 x 1016operations Operation frepuency ≤ 7200 operations/h ≤ 7200 operations/h Insulation voltagesRated insulation voltage AC ≥ 2.0 kVAC (rms) ≥ 2.0 kVAC (rms)(Cont./elect.)(Cont./elect.) DC NoneNoneRated impulse withstand voltage AC 4 kV (1.2/50 µs) 4 kV (1.2/50 µs) (cont./elect.) (IEC 60664) (cont./elect.) (IEC 60664)DC 800 V 800 VSpecifications are subject to change without notice (30.05.2014) 1

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo

Top