Orario di servizio: Lunedì a Venerdì 9:00-18:00
LS-H901-Y - LS-H901-Y PANASONIC Sensor head, retro reflective, range 1m, cable 2m, without reflector
Disponibile Prodotto più richiesto

LS-H901-Y

LS-H901-Y PANASONIC Sensor head, retro reflective, range 1m, cable 2m, without reflector

$0.00USD
3232 in magazzino
Specifiche chiave
Articolo:Specifications
Cavo:0.15 mm22-core two parallel shielded cables, 2 m 6.562 ft long(Note:Cable cannot be extended.)
Peso:Net weight: 50 g approx.Gross weight: 85 g approx.
Dettagli:Sensor heads(Coaxial retroreflective type)
Informazioni fornitore
PANASONIC
PANASONIC
Prodotti: 4316
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
ArticoloSpecifications
Cavo0.15 mm22-core two parallel shielded cables, 2 m 6.562 ft long(Note:Cable cannot be extended.)
PesoNet weight: 50 g approx.Gross weight: 85 g approx.
DettagliSensor heads(Coaxial retroreflective type)
ProdottoAmplifier-separated Type Digital Laser Sensor
MaterialeEnclosure: PBTIndicator cover: PolycarbonateBeam-emitting / receiving surfaces: Glass
AccessorioMS-LS-1(Mounting bracket): 1pc.RF-330(Refrector): 1pc.
Dimensione del puntoApprox. dia. 6 mm dia. 0.236 in or less (at a distance from the sensor head of 1 m 3.281 ft)
ProtezioneIP40 (IEC)
Numero di parteLS-H901-Y
Nome del prodottoAmplifier-separated Type Digital Laser Sensor LS-500
Numero di prodottoLS-H901-Y
Oggetto di rilevamentoOpaque, translucent, or transparent object(Note:Make sure to confirm detection with an actual sensor before use.)
Umidità ambientale35 to 85 % RH, Storage: 35 to 85 % RH
Resistenza agli urti100 m / s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Campo di rilevamento: HYPR0.01 to 2.5m0.033 to 8.202 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Campo di rilevamento: U-LG0.01 to 2m0.033 to 6.562 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Illuminazione ambientaleIncandescent light: 3,000 ℓx or less at the light-receiving face
Temperatura ambiente-10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit
Indicatore di funzionamentoOrange LED (lights up when the amplifier output is ON)
Resistenza alle vibrazioni10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each
Amplificatori applicabiliLS-501(P), LS-501(P)-C2(Note:When using the thru-beam typeLS-H101□orLS-H102□, do not set the receiving light sensitivity (gctL) of the applicableLS-500series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.)
Elemento emittente:TipoRed semiconductor laser diode
Resistenza di isolamento20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Campo di rilevamento: modalità STD0.01 to 1m0.033 to 3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Campo di rilevamento: modalità FAST0.01 to 1m0.033 to 3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Campo di rilevamento: modalità H-SP0.01 to 1m0.033 to 3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Campo di rilevamento: modalità U-LG0.01 to 1.5m0.033 to 4.921 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Resistenza alla tensione1,000 V AC for one min. between all supply terminals connected together and enclosure
Elemento emittente: Classe laserClass 1 [IEC / JIS / FDA](Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and )Radiological Health) under the FDA (Food and Drug Administration).
Elemento emittente: potenza massima1mW
Conformità alla direttiva sulla marcatura CEEMC Directive, RoHS Directive
Elemento emittente: lunghezza d'onda di emissione di picco660 nm 0.026 mil

Descrizione del prodotto

More details
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo

Top