ParametroValore
ArticoloSpecifications
PesoNet weight: 300 g approx.
DettagliController
ProdottoUltra High-speed Laser Displacement Sensor [CCD Style]
Accessorio-
Numero di parteHL-C1C-M
Uscita allarmePhoto-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between alarm output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
Lunghezza del cavoPower line: Less than 10 m 32.808 ftSignal line: Less than 30 m 98.425 ft
Nome del prodottoUltra High-speed Laser Displacement Sensor HL-C1(Discontinued)
Frequenza di campionamentoSelectable from 100 micro s / 144 micro s / 200 micro s / 255 micro s / 332 micro s / 498 micro s / 1,000 micro s
Funzioni di attesaSelectable from NORMAL / P-P / PEAK / VALLEY(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Numero di prodottoHL-C1C-M
Tensione di alimentazione24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Filtri digitaliHigh pass: OFF, 10 to 2,000 Hz (9 steps)Low pass: OFF, 10 to 2,000 Hz (9 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Indicatori: SCURORed LED (lights up upon disabled measurement due to insufficient light at sensor head 1 or 2)
Ingresso azzerato ONZero set: ON when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Calibrazione: Span0.9000 to 1.1000(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Ingresso di azzeramento OFFZero set: OFF when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Calibrazione: Spostamentoplus or minus 20.0000 mm plus or minus 0.787 in(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Consumo attualeWhen 1 sensor is connected: 430 mA approx.When 2 sensors are connected: 550 mA approx.
Indicatori: LUMINOSIRed LED (lights up upon disabled measurement due to excessive light at sensor head 1 or 2)
Funzioni di calcoloL plus or minus KA, L plus or minus KB, L plus or minus K (A plus or minus B)A, B: Sensor head 1, Sensor head 2 measurement values, L = plus or minus 999.9999, K = 0.0001 to 99.9999(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Ingresso/uscita serialeRS-232C
Testa del sensore ConnectaleMaximum 2 sensor heads
Uscita analogica: correnteOutput current: 4 to 20 mA/F.S. [default setting when diffuse reflective mode is selected (Note 2)]Output range: 0 to 29.5 mA (maximum of 25 mA at max. load impedance)Load impedance: 250 Ohm or less(Note 1) The maximum analog output current will vary with load impedance.(Note 2) If specular reflective mode is selected, then the default setting is 5.6 to 18.4 mA/F.S.
Uscita analogica: tensioneOutput voltage: plus or minus 5 V/F.S. [default setting when diffuse reflective mode is selected (Note) ]Output range: -10.9 to +10.9 VOutput current: Max. 2 mA, Output impedance: 50 Ohm(Note) If specular reflective mode is selected, then the default setting is plus or minus 4 V/F.S.
Numero medio di campioniOFF, 2 to 32,768 times (16 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Risultati del giudizio (O1, O2)Photo-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between judgment output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
Indicatori: Emissione laserGreen LED (lights up during laser emission from sensor head 1 or sensor head 2, or immediately before laser emission)
Caratteristiche di temperaturaplus or minus 0.01 % F.S./degrees
Input di temporizzazione (emissione laser)Laser emission stops or continues when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input or there is an open circuit: determined based on input mode selection.
Uscita allarme: funzionamento dell'uscitaOpened when the amount of light is excessive or insufficient.
Uscita allarme: protezione da cortocircuitoIncorporated
Resistenza ambientale: Umidità ambientale35 to 85 % RH, Storage: 35 to 85 % RH
Resistenza ambientale: Resistenza agli urti196 m/s2 (20 G approx.) in X, Y and Z directions for 3 times each
Uscite di giudizio (O1, O2): operazione di uscitaOpened or closed when the threshold value is reached. Determined based on judgment output mode selection. (The threshold value varies with the hysteresis setting.)
Resistenza ambientale: Temperatura ambiente0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Resistenza ambientale: Resistenza alle vibrazioni10 to 55 Hz frequency (period: 1 min.) 0.75 mm 0.030 in amplitude in X,Y and Z directions for 30 min. each
Risultati del giudizio (O1, O2): Categoria di utilizzoDC-12 or DC-13
Uscite di giudizio (O1, O2): protezione da cortocircuitoIncorporated