| Parametro | Valore |
|---|---|
| Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. | |
| Larghezza | 34.2 mm |
| Altezza | 41.8 mm |
| Lunghezza | 14.6 mm |
| Serie | HC-M-02 |
| Generale | For HEAVYCON housing type B6 to B48, HC-M-MHR... hinged retaining frame required |
| Applicazione | Power |
| Tipo di prodotto | Modular contact insert |
| Nota di montaggio | - Connection of the wires using a 2 mm Allen wrench.- Housing height ≥ 52 mm.- Axial screw connection only for flexible wires.- Plug-in connections may only be operated only when there is no load/voltage. |
| Corrente nominale | 40 A |
| Materiale di contatto | Copper alloy |
| Presa esagonale | SW 2 |
| Numerazione dei contatti | 1 - 2 |
| Coppia di serraggio | 1.5 Nm (2.5 mm² ... 4 mm²) |
| Profilo di connessione | 2 |
| Grado di inquinamento | 3 |
| Disegno dimensionale | |
| Numero di posizioni | 2 |
| Tensione di sovratensione nominale | 8 kV |
| Categoria di sovratensione | III |
| Tecnologia di connessione | Axial screw connection |
| Tensione nominale (III/3) | 1000 V |
| Numero di slot del modulo | 1 |
| Sezione trasversale del conduttore | 2.5 mm² ... 8 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Materiale portante del contatto | PC |
| Materiale della superficie di contatto | Ag |
| Cicli di inserimento/ritiro | ≥ 500 |
| Sezione trasversale di collegamento AWG | 12 ... 10 |
| Temperatura ambiente (funzionamento) | -40 °C ... 125 °C |
| Collegamento secondo lo standard | IEC / EN |
| Grado di infiammabilità secondo UL 94 | V0 |
| Lunghezza di spelatura del singolo filo | 8 mm +1 mm (for 6 mm²) |