HC-M-02-AT-M-25

HC-M-02-AT-M-25 1421377 PHOENIX CONTACT Module inserts contact HC-M-02-AT-M-25 1421377

$0.00USD
3215 in magazzino
Specifiche chiave
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Generale:For HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
Applicazione:Power
Corrente nominale:100 A
Informazioni fornitore
Prodotti: 0
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
GeneraleFor HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
ApplicazionePower
Corrente nominale100 A
Grado di inquinamento3
Numero di posizioni2
Tensione di sovratensione nominale8 kV
Categoria di sovratensioneIII
Istruzioni di montaggioTo ensure correct use, installation in housing with IP54 protection or better is required
Tensione nominale (III/3)1000 V
Grado di infiammabilità secondo UL 94V0
Lunghezza di spelatura del singolo filo13 mm

Descrizione del prodotto

Contact insert module, Pin, Axial screw connection, 1000 V, 100 A, 10 mm2 ... 25 mm2, application: Power