Orario di servizio: Lunedì a Venerdì 9:00-18:00
HC-K 6/12-ESTS - HC-K 6/12-ESTS 1636350 PHOENIX CONTACT Contact insert
Disponibile Prodotto più richiesto

HC-K 6/12-ESTS

HC-K 6/12-ESTS 1636350 PHOENIX CONTACT Contact insert

$114.79USD
128 in magazzino
Specifiche chiave
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Tipo:B16
Larghezza:34 mm
Altezza:47.2 mm
Informazioni fornitore
Prodotti: 0
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
TipoB16
Larghezza34 mm
Altezza47.2 mm
Lunghezza84.5 mm
SerieHC-K
GeneraleFor HEAVYCON ADVANCE and HEAVYCON housing of type B16/B32, axial connection for 2 mm Allen wrench
ApplicazionePower/signal
Tipo di prodottoContact insert with a fixed no. of positions
Nota di montaggioTo ensure correct use, installation in housing with IP54 protection or better is required
Corrente nominale40 A (power contacts)
Revisione dell'articolo04
Diametro di contatto4 mm
Materiale di contattoCu alloy
Numerazione dei contatti1 - 6 (power contacts)
Lama del cacciavite0.5 x 3.5 mm (control contacts)
Coppia di serraggio2 Nm ... 2.5 Nm (PE connection)
Profilo di connessione6+12+PE
Grado di inquinamento3
Disegno dimensionale
Numero di posizioni18
Tensione di sovratensione nominale8 kV (power contacts)
Categoria di sovratensioneIII
Tecnologia di connessioneAxial screw connection (power contacts)
Tipo di materiale di contattoturned
Numero di contatti di potenza6
Tensione nominale (III/3)690 V
Sezione trasversale del conduttore2.5 mm² ... 10 mm² (power contacts)
Numero di contatti di controllo12
Materiale portante del contattoPC
Cicli di inserimento/ritiro≥ 500
Sezione trasversale di collegamento AWG12 ... 8 (power contacts)
Temperatura ambiente (funzionamento)-40 °C ... 125 °C
Distanza del foro di perforazione, orizzontale77.5 mm
Tensione nominale per i contatti di potenza230/400 V
Grado di infiammabilità secondo UL 94V0
Lunghezza di spelatura del singolo filo8 mm +1 mm (Power 6 mm² ... 10 mm²)
Materiale della superficie di contatto, contatto di potenzaAg
Materiale della superficie di contatto, contatto di controlloAg

Descrizione del prodotto

Contact insert, number of poles: 6+12+PE, size: B16, power contacts: 6, control contacts: 12, Male, Axial screw connection, 690 V, 40 A, 2.5 mm² ... 10 mm², application: Power/signal
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo

Top