Orario di servizio: Lunedì a Venerdì 9:00-18:00
FEQDB3MK/6 - FEQDB3MK/6 431139 GENERAL ELECTRIC FE250-RCD DiffBottom-3p 220-440V AC
Disponibile Prodotto più richiesto

FEQDB3MK/6

FEQDB3MK/6 431139 GENERAL ELECTRIC FE250-RCD DiffBottom-3p 220-440V AC

$0.00USD
3914 in magazzino
Specifiche chiave
Stato:Active
ETIM 5.0 (DIMENSIONI):EC001021
ETIM 6.0 (DIMENSIONI):EC001021
Peso (SPECIFICHE):0.825 kg
Informazioni fornitore
Prodotti: 0
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
StatoActive
ETIM 5.0 (DIMENSIONI)EC001021
ETIM 6.0 (DIMENSIONI)EC001021
Peso (SPECIFICHE)0.825 kg
Intervallo (STATO ORDINE/CONSEGNA)Protection
Serie (STATO ORDINE/CONSEGNA)Residual Current devices
Tipo di frame (STATO ORDINE/CONSEGNA)E frame (160A/250A)
Misure (STATO ORDINE/CONSEGNA)80x105x95 mm
Numero di poli (STATO ORDINE/CONSEGNA)3P
Dettaglio accessorio (STATO ORDINE/CONSEGNA)Differential bottom
Imballaggio standard (STATO ORDINE/CONSEGNA)1

Descrizione del prodotto

More details
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Dettagli tecnici

A record plus circuit breaker can offer protection against earth leakage currents by using an add-on residual current device (RCD). A line of three pole completely integrated add-on devices are available as side mounted models (FD frame size) or as units that are fitted below the trip unit of the breaker (FD, FE and FG frame sizes). In all cases the RCD unit interfaces directly with the circuit breaker without the use of any secondary wiring connections. Earth RCD has a sensor placed around the phase and neutral current paths that detects the vectorial sum of the phase and neutral currents. When this sum is no longer zero it is assumed that current is flowing to earth (residual current). If this value exceeds the threshold set on the RCD the breaker connected to the device is tripped.The RCD units electrical power is supplied by the line voltage of the breaker it is linked to. By use of a multi-phase bridge the design still works when one phase and the neutral is present. A pouch on the RCD allows one to place one BAT contact NO or NC which allows a remote signal on earth faults. A Record Plus breaker and an RCD combination can be connected like any stand-alone breaker and are available as fixed or plug-in devices. The mains connection interface of the RCD is an exact replica of the breaker connection area, thus allowing the use of all standard breaker terminals.

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo

Top