Specifiche chiave
1.631 (F3SJ-A____P14/P30):180
Modello (F3SJ-A____P14/P30):Protected height (mm)
Materiale (F3SJ-A____P14/P30):Casing (including metal parts on both ends): Aluminum, zinc die-castCap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC
Ricevitore (F3SJ-A____P14/P30):Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensityError mode indicators (red LED × 3): Blink to indicate error detailsOFF output indicator (red LED × 1): ON when safety output is OFF, blinks at lockout.ON output indicator (green LED × 1): ON while safety output is ONMuting error indicator, Blanking/test indicator (green LED × 2): ON/flash according to function
Informazioni fornitore
OMRON
OMRON
Prodotti: 41472
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
1.631 (F3SJ-A____P14/P30)180
Modello (F3SJ-A____P14/P30)Protected height (mm)
Materiale (F3SJ-A____P14/P30)Casing (including metal parts on both ends): Aluminum, zinc die-castCap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC
Ricevitore (F3SJ-A____P14/P30)Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensityError mode indicators (red LED × 3): Blink to indicate error detailsOFF output indicator (red LED × 1): ON when safety output is OFF, blinks at lockout.ON output indicator (green LED × 1): ON while safety output is ONMuting error indicator, Blanking/test indicator (green LED × 2): ON/flash according to function
Condizione (F3SJ-A____P14/P30)1 set
Indicatore (F3SJ-A____P14/P30)Emitter
Da 281 a 389 (F3SJ-A____P14/P30)30 to 42
Da 407 a 497 (F3SJ-A____P14/P30)44 to 54
Da 420 a 720 (F3SJ-A____P14/P30)17 to 29
Da 515 a 605 (F3SJ-A____P14/P30)56 to 66
623 a 731 (F3SJ-A____P14/P30)68 to 80
Da 767 a 983 (F3SJ-A____P14/P30)84 to 108
Accessori (F3SJ-A____P14/P30)Test rod (*1), instruction manual, standard mounting bracket (F39-LJ1 bracket for top/bottom mounting), mounting brackets (intermediate) (*2), error mode label, User's Manual (CD-ROM)*1. The F3SJ-A☐☐☐☐55 is not included.*2. Number of intermediate brackets depends on protective height of F3SJ.For protective height from 600 to 1,130 mm : 1 set for each of the emitter and receiver is includedFor protective height from 1,136 to 1,658 mm: 2 sets for each of the emitter and receiver are includedFor protective height from 1,660 to 2,180 mm : 3 sets for each of the emitter and receiver are includedFor protective height from 2,195 to 2,500 mm : 4 sets for each of the emitter and receiver are included
Da 745 a 1.045 (F3SJ-A____P14/P30)30 to 42
Tensione di ingresso (F3SJ-A____P14/P30)Test input, interlock selection input, reset input, and muting input are allON voltage: 9 to 24 V (Vs) (sink current: 3 mA max.), OFF voltage: 0 to 1.5 V, or openExternal device monitoring inputON voltage: 9 to 24 V (Vs) (sink current: 5 mA max.), OFF voltage: 0 to 1.5 V, or open
Funzione di prova (F3SJ-A____P14/P30)Self test (at power-ON and at power distribution)External test (emission stop function by test input)
Da 1.055 a 1.271 (F3SJ-A____P14/P30)116 to 140
Da 1.070 a 1.295 (F3SJ-A____P14/P30)43 to 52
Da 1.343 a 1.559 (F3SJ-A____P14/P30)148 to 172
Da 1.395 a 1.620 (F3SJ-A____P14/P30)56 to 65
Da 1.745 a 1.995 (F3SJ-A____P14/P30)70 to 80
Da 2.120 a 2.495 (F3SJ-A____P14/P30)85 to 100
10 (Specifiche e informazioni per l'ordine)245
12 (Specifiche e informazioni per l'ordine)295
16 (Specifiche e informazioni per l'ordine)395
19 (Specifiche e informazioni per l'ordine)470
21 (Specifiche e informazioni per l'ordine)520
22 (Specifiche e informazioni per l'ordine)545
23 (Specifiche e informazioni per l'ordine)570
25 (Specifiche e informazioni per l'ordine)620
26 (Specifiche e informazioni per l'ordine)245
28 (Specifiche e informazioni per l'ordine)263
29 (Specifiche e informazioni per l'ordine)720
32 (Specifiche e informazioni per l'ordine)795
34 (Specifiche e informazioni per l'ordine)317
35 (Specifiche e informazioni per l'ordine)870
37 (Specifiche e informazioni per l'ordine)920
38 (Specifiche e informazioni per l'ordine)945
41 (Specifiche e informazioni per l'ordine)1,020
42 (Specifiche e informazioni per l'ordine)389
44 (Specifiche e informazioni per l'ordine)1,095
45 (Specifiche e informazioni per l'ordine)1,120
48 (Specifiche e informazioni per l'ordine)1,195
50 (Specifiche e informazioni per l'ordine)461
51 (Specifiche e informazioni per l'ordine)1,270
56 (Specifiche e informazioni per l'ordine)1,395
60 (Specifiche e informazioni per l'ordine)551
65 (Specifiche e informazioni per l'ordine)1,620
68 (Specifiche e informazioni per l'ordine)623
70 (Specifiche e informazioni per l'ordine)1,745
75 (Specifiche e informazioni per l'ordine)1,870
76 (Specifiche e informazioni per l'ordine)695
80 (Specifiche e informazioni per l'ordine)1,995
88 (Specifiche e informazioni per l'ordine)803
90 (Specifiche e informazioni per l'ordine)2,245
95 (Specifiche e informazioni per l'ordine)2,370
96 (Specifiche e informazioni per l'ordine)875
100 (Specifiche e informazioni per l'ordine)2,495
108 (Specifiche e informazioni per l'ordine)983
116 (Specifiche e informazioni per l'ordine)1,055
124 (Specifiche e informazioni per l'ordine)1,127
132 (Specifiche e informazioni per l'ordine)1,199
140 (Specifiche e informazioni per l'ordine)1,271
Umidità ambiente (F3SJ-A____P14/P30)Operating: 35% to 85% (no condensation), Storage: 35% to 95%
Resistenza agli urti (F3SJ-A____P14/P30)Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions
Metodo di connessione (F3SJ-A____P14/P30)Connector method (M12, 8-pin)
Collegamento in serie (F3SJ-A____P14/P30)Time division emission by series connectionNumber of connections: up to 4 sets (F3SJ-A only) F3SJ-E, F3SJ-B and F3SJ-TS cannot be connected.Total number of beams: up to 400 beamsMaximum cable length for 2 sets: no longer than 15 m
Peso (imballato) (F3SJ-A____P14/P30)Calculate using the following expressions:(1) For F3SJ-A____14, weight (g) = (protective height) x 1.7 +α(2) F3SJ-A____30, weight (g) = (protective height) x 1.5 +αThe values forαare as follows:Protected height 245 to 596 mm: = 1,100 protected height 1,660 to 2,180 mm: = 2,400Protected height 600 to 1,130 mm: = 1,500 protected height 2,195 to 2,500 mm: = 2,600Protected height 1,136 to 1,658 mm: = 2,000
Tensione di tenuta (F3SJ-A____P14/P30)1,000 VAC 50/60 Hz, 1 min
Circuito di protezione (F3SJ-A____P14/P30)Output short-circuit protection, and power supply reverse polarity protection
Temperatura ambiente (F3SJ-A____P14/P30)Operating: -10 to 55°C (no icing), Storage: -30 to 70°C
Serie F3SJ-A____14 (F3SJ-A____P14/P30)245 to 263
Serie F3SJ-A____30 (F3SJ-A____P14/P30)245 to 395
Norme applicabili (F3SJ-A____P14/P30)IEC 61496-1, EN 61496-1 UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment)IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices)IEC 61508-1 to -3, EN 61508-1 to -3 SIL3IEC 13849-1: 2006, EN ISO 13849-1: 2008 (PLe, Cat.4)UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
Grado di protezione (F3SJ-A____P14/P30)IP65 (IEC 60529)
Resistenza alle vibrazioni (F3SJ-A____P14/P30)Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
Resistenza di isolamento (F3SJ-A____P14/P30)20 MΩ min. (at 500 VDC)
Da 0,2 a 7 m (Specifiche e informazioni per l'ordine)1,745 to 2,495
Applicazione (Specifiche e informazioni per l'ordine)Detection capability
Funzioni relative alla sicurezza (F3SJ-A____P14/P30)Start interlock, restart interlock (Must be set with a setting tool when the muting function is used.)External device monitorMuting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.)Fixed blanking (must be set by a setting tool)Floating blanking (must be set by a setting tool)
Non utilizzare lampade a incandescenza (F3SJ-A____P14/P30)100 m
Numero di travi (Specifiche e informazioni per l'ordine)Protective height (mm)2
Protezione per le dita (Specifiche e informazioni per l'ordine)Dia. 14 mm
Protezione mani/braccia (Specifiche e informazioni per l'ordine)Dia. 30 mm
Intensità luminosa ambientale operativa (F3SJ-A____P14/P30)Incandescent lamp: receiving-surface light intensity of 3,000 lx max., Sunlight: receiving-surface light intensity of 10,000 lx max.
Funzione di prevenzione delle interferenze reciproche (F3SJ-A____P14/P30)Interference light prevention algorithm, sensing distance change function
(Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Laser pointer for F3SJ
Utilizzo di una lampada a incandescenza per l'uscita dell'indicatore esterno 1 (F3SJ-A____P14/P30)60 m
Utilizzo di una lampada a incandescenza per l'uscita dell'indicatore esterno 2 (F3SJ-A____P14/P30)40 m
7 m (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))F39-JD7A
10 m (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))F39-JD10A
15 m (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))F39-JD15A
20 m (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))F39-JD20A
Modello (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))F3SJ-A____P14
Emettitore (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached (Operation mode can be changed with the setting tool.)External indicator output 2 : ON when lock-out for a basic system (Operation mode can be changed with the setting tool.)ON when muting/override for a muting system (Operation mode can be changed with the setting tool.)
Versione (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Ver. 2
Ricevitore (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max.,151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max.
Da OFF a ON (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))1 set,0245 to 983: 44 ms to 70 ms max.1,055 or higher: 80 ms to 100 ms max.
Aspetto (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Output
Tipo di sensore (cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Type 4 safety light curtain
Distanza tra i raggi (P) (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))9 mm
Diametro della lente (cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Diameter 5 mm
Campo di funzionamento (cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))0.2 to 9 m (protective height 1,640 mm max.), 0.2 to 7 m (protective height 1,655 mm min.)(Depending on the setting tool, the detection distance can be shortened to 0.5 m.)
Categoria di sicurezza (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Safety purpose of category 4, 3, 2, 1, or B
Numero di fasci (n) (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))26 to 180
Capacità di rilevamento (cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Opaque objects 14 mm in diameter
Tempo di attesa all'avvio (cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))2 s max. (2.2 s max. for series connection)
Utilizzo di lampada a incandescenza per uscita ausiliaria e uscita indicatore esterno (F3SJ-A____P14/P30)45 m
Modalità di funzionamento in uscita (cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Receiver
Uscite di sicurezza (OSSD) (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),allowable capacity load 2.2 μF, leak current 1 mA max.(This can be different from traditional logic (ON/OFF) because safety circuit is used.)
Altezza di protezione (PH) (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))245 to 1,631 mm
Collegamento dello strumento di impostazione (cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Connectable
Tensione di alimentazione (Vs) (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))24 VDC±20% (ripple p-p10% max.)
Consumo di corrente (senza carico) (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Emitter
Angolo di apertura effettivo (EAA) (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Based on IEC 61496-2.Within±2.5° for both emitter and receiver when the detection distance is 3 m or over
Sorgente luminosa (lunghezza d'onda emessa) (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Infrared LED (870 nm)
Uscita ausiliaria 1 (uscita non di sicurezza) (cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),leak current 1 mA max.
Uscita indicatore esterno (uscita non di sicurezza) (cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))Available indicatorsIncandescent lamp : 24 VDC, 3 to 7 WLED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max.(To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.)
Tempo di risposta (in condizioni di luce incidente stabile) (cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))ON to OFF
Uscita ausiliaria 2 (Uscita non di sicurezza. Funzione per sistema base.) (Cavo connettore a estremità singola (2 cavi per set, per emettitore e ricevitore))One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),leak current 1 mA max.

Descrizione del prodotto

More details
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Dettagli tecnici

Application

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo

Top