| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong |
| Produzione | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 26.4 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) |
| Dettagli | Retroreflective type |
| Prodotto | Amplifier Built-in Ultra-compact Laser Sensor |
| Materiale | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessorio | RF-330 (Reflector): 1 pc.MS-EXL2-3 (Mounting plate): 1 pc. |
| Isteresi | 20 % or less of operation distance |
| Protezione | IP67 (IEC) |
| Numero di parte | EX-L291-P-C5 |
| Nome del prodotto | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Ripetibilità | Perpendicular to sensing axis: 0.2 mm0.0080 inor less |
| Tempo di risposta | 0.5 ms or less |
| Campo di rilevamento | 4 m13.123 ft(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Numero di prodotto | EX-L291-P-C5 |
| Oggetto di rilevamento | Opaque translucent object of ø25 mmø0.984 inor more |
| Tensione di alimentazione | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Prolunga del cavo | Extension up to total 50 m164.042 ftis possible with 0.3 mm2, or more, cable. |
| Umidità ambientale | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Elemento emittente | Red semiconductor laser Class 1 (IEC / JIS/ FDA) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 390 μW, Peak emission wavelength: 655 nm0.026 mil) |
| Resistenza agli urti | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Illuminazione ambientale | Incandescent light: 3,000 lx or less at the light-receiving face |
| Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Consumo attuale | 15 mA or less |
| Regolatore di sensibilità | Continuously variable adjuster |
| Resistenza alle vibrazioni | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Resistenza di isolamento | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Output:Operazione di output | Light-ON / Dark-ON selectable by the output operation switching input |
| Resistenza alla tensione | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Dimensioni del punto di emissione (tipico) | Approx. 6 × 4 mm0.236 × 0.157 in(vertical x horizontal)(at a sensing distance of 1 m)(Note) In the case sensing distance is 4 m 13.123 ft, the emission spot size is H 18 x W 10 mmH 0.709 x W 0.394 in(visual reference value). |
| Conformità alla direttiva sulla marcatura CE | EMC Directive, RoHS Directive |
| Uscita: protezione da cortocircuito | Incorporated (short-circuit protection / inverse polarity protection) |
| Oggetto minimo di rilevamento (tipico) | - |
| Funzione di prevenzione automatica delle interferenze | Incorporated(Two sensors can be mounted close together.) |
| Ripetibilità (tipica) (perpendicolare all'asse di rilevamento) | - |
Specifiche tecniche e dati di prestazione