| Parametro | Valore |
|---|---|
| Articolo | Specifications |
| Cavo | 0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong |
| Produzione | NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 26.4 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
| Dettagli | Spot reflective type |
| Prodotto | Amplifier Built-in Ultra-compact Laser Sensor |
| Materiale | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessorio | MS-EXL2-3 (Mounting plate): 1 pc. |
| Isteresi | 20 % or less of operation distance |
| Protezione | IP67 (IEC) |
| Numero di parte | EX-L221-C5 |
| Nome del prodotto | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Ripetibilità | Perpendicular to sensing axis: 0.05 mm0.0020 inor less |
| Tempo di risposta | 0.5 ms or less |
| Campo di rilevamento | 45 to 300 mm1.772 to 11.811 in(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Numero di prodotto | EX-L221-C5 |
| Oggetto di rilevamento | ø1 mmø0.039 inor less(at a sensing distance of 300 mm) |
| Tensione di alimentazione | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Prolunga del cavo | Extension up to total 50 m164.042 ftis possible with 0.3 mm2, or more, cable. |
| Umidità ambientale | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Elemento emittente | Red semiconductor laser Class 1 (IEC / JIS/ FDA) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 390 μW, Peak emission wavelength: 655 nm0.026 mil) |
| Resistenza agli urti | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Illuminazione ambientale | Incandescent light: 3,000 lx or less at the light-receiving face |
| Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Consumo attuale | 15 mA or less |
| Regolatore di sensibilità | Continuously variable adjuster |
| Resistenza alle vibrazioni | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Resistenza di isolamento | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Output:Operazione di output | Light-ON / Dark-ON selectable by the output operation switching input |
| Resistenza alla tensione | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Dimensioni del punto di emissione (tipico) | ø1 mmø0.039 inor less(at a sensing distance of 300 mm) |
| Conformità alla direttiva sulla marcatura CE | EMC Directive, RoHS Directive |
| Uscita: protezione da cortocircuito | Incorporated (short-circuit protection / inverse polarity protection) |
| Oggetto minimo di rilevamento (tipico) | Gold wire of ø0.01 mmø0.0004 in(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
| Funzione di prevenzione automatica delle interferenze | Incorporated(Two sensors can be mounted close together.) |
| Ripetibilità (tipica) (perpendicolare all'asse di rilevamento) | 0.02 mm0.0008 inor less(at 100 to 200 mm sensing distance)(Note)Typical values when the sensitivity adjuster is optimally adjusted. |