Orario di servizio: Lunedì a Venerdì 9:00-18:00
ER-TF04-EX - ER-TF04-EX PANASONIC Wide-area fan type ionizer, 4 air outlets, 400mm, 100-240VDC
Disponibile Prodotto più richiesto

ER-TF04-EX

ER-TF04-EX PANASONIC Wide-area fan type ionizer, 4 air outlets, 400mm, 100-240VDC

$0.00USD
3236 in magazzino
Specifiche chiave
Articolo:Specifications
Peso:1.0 kg approx.
Dettagli:Wide-area fan type
Prodotto:Wide-area Ionizer
Informazioni fornitore
PANASONIC
PANASONIC
Prodotti: 4316
Di solito spedito entro 2-3 giorni lavorativi
Qualità garantita
Spedizione veloce
Supporto tecnico

Specifiche tecniche

ParametroValore
ArticoloSpecifications
Peso1.0 kg approx.
DettagliWide-area fan type
ProdottoWide-area Ionizer
MaterialeBar unit enclosure: ABS, Fan unit enclosure: ABS, Discharge needles: Tungsten, Mounting bracket: SPCC
AccessoriAC adapter (Note), F.G. connection cable: 1 pc., Spare replacement filters: 5 pcs., Three-pronged outlet with ground pin: 1 pc., Blindfold seals: 2 sheets(Note:Please prepare an AC cable separately as it is needed.The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL))
Equilibrio ionicoplus or minus10 V or less(Note:Typical value at a distance of 300 mm 11.811 in from the front surface of the air outlet at the unit center at maximum fan speed.)
Numero di parteER-TF04-EX
Nome del prodottoWide-area Ionizer ER-TF(Discontinued)
Numero di prodottoER-TF04-EX
Tensione di alimentazioneAccessory AC adapter input: 100 to 240 V AC plus or minus10 % 50/60 Hz(Output: 24 V DC)
Umidità ambientale35 to 65 % RH (No dew condensation)
Metodo di scaricoSteady-state DC
generazione di ozono0.02 ppm or less(Note: Typical value at a distance of 300 mm 11.811 in from the front surface of the air outlet at the unit center at maximum fan speed.)
Consumo energetico80 VA or less (at 100 V: 70 VA or less)
Temperatura ambiente0 to + 50 ℃+ 32 to + 122℉(No dew condensation),AC adapter: 0 to + 40 ℃+ 32 to + 104℉
Tempo di rimozione della carica1 sec. approx. (±1,000 V → ±100 V)(Note: Typical value at a distance of 200 mm 7.874 in from the front surface of the air outlet at the unit center at maximum fan speed.)
Errore di output (ERROR)NPN open-collector transistor• Maximum sink current: 50 mA• Applied voltage: 30 V DC or less (between output and 0 V)• Residual voltage: 1 V or less (at 50 mA sink current)
Indicatori:Barra:CONTROLLAOrange LED (Lights up when discharge part check or fan check is detected)
Indicatori:Barra:ERRORERed LED (Lights up when discharge part error or fan error is detected)
Indicatori:Barra:POTENZAGreen LED (Lights up when power supplied)
Tensione di uscita di scaricaplus or minus6,000 V approx.
Indicatori: Ventola: Stato della ventolaYellow LED (Lights up when fan error or fan check is detected)
Errore di output: operazione di outputOFF if abnormal discharge, object inserted into discharge window or fan problem detected; normally ON
Direttive conformi alla marcatura CEEMC Directive, RoHS Directive
Indicatori: Ventilatore: Stato della parte di scaricoYellow LED (Lights up when discharge part error or discharge part check is detected)
Uscita di errore: protezione da cortocircuitoIncorporated

Descrizione del prodotto

More details
Caratteristiche principali
  • Qualità di grado industriale
  • Conforme RoHS
  • Certificato CE
  • Garanzia di 1 anno

Documenti del prodotto

Scheda tecnica

Specifiche tecniche e dati di prestazione

Manuale utente

Guida di installazione e utilizzo

Top