| Parametro | Valore |
|---|---|
| AWG | similar to AWG 18 |
| EAN | 4048879416160 |
| Modulo | 41101 |
| Scudo | no |
| eClass | 27279218 |
| Alloggiamento | Black plastic (gray on request) |
| Art.No.: | 7000-41101-0560150 |
| Materiale | MSUD (PBT); M12 (PUR) |
| Ø esterno | 5.2 mm ±5% |
| Tipo di cavo | 5 (PUR schweißfunkenbeständig) |
| Protezione | IP67 inserted and tightened (EN 60529) |
| display a LED | yellow |
| Colore della giacca | yellow |
| Tensione di prova | 2 500 V AC |
| Velocità di torsione | 35 cycles/min |
| Colore (giacca) | yellow |
| Gruppo di materiali | IEC 60664-1, category I |
| Unità di imballaggio | 1 |
| sforzo di torsione | ±360°/m |
| Isolamento dei fili | PP (bk num, gnye) |
| Diametro (nucleo) | 3 × 0.75 mm² |
| Materiale (filo) | Cu wire, bare |
| Tensione nominale | 300 V AC |
| Resistore (nucleo) | max. 26 Ω/km (20 °C) |
| Disattivare l'orario di punta | max. 55 V |
| Approvazione (cavo) | cRUus (AWM-Style 20549/10493); CE conform |
| Materiale di bloccaggio | Zinc die casting, matte nickel plated |
| Blocco delle porte | M2.5/M12 (recommended torque 0.4/0.6 Nm) |
| Grado di inquinamento | 3 |
| Ghiandola di compressione | M12 (SW13) |
| Materiale (giacca) | PUR (UL/CSA), welding spark |
| Tensione di esercizio | 24 V AC ±20% / DC ±25% |
| Ø esterno (rivestimento) | 5.2 mm ±5% |
| Intervallo di temperatura | -25...+85 °C, depending on cable quality |
| paese di origine | CZ |
| Proprietà del binario C | 10 Mio. |
| Peso del cavo [g/m] | 48,40 |
| resistenza termica | flame retardant UL, FT2, IEC 60332-1, IEC 60332-2-2, welding spark resistant |
| Raggio di curvatura (fisso) | 5 × outer Ø |
| Costruzione (nucleo) | 42 × 0.15 mm (multi-strand wire class 6) |
| Consumo attuale | approx. 12 mA |
| Tensione di sovratensione nominale | 0.8 kV |
| resistenza chimica | good resistance to oil, gasoline and chemicals (EN 60811-404) |
| Prodotto alternativo: | Product ComparisonMSUDForm C (8 mm) – M12, male 90°24 V AC ±20% / DC ±25%LED and suppressionFurther cable lengths on request. Plastic housings with good resistance against chemicals and oils. The resistance to aggressive media should be individually tested for your application. Further details on request.FormForm41101CablesNo./diameter of wires3 × 0.75 mm²Wire isolationPP (bk num, gnye)C-track properties10 Mio.Material (jacket)PUR (UL/CSA), welding sparkOuter Ø5.2 mm ±5%Bend radius (moving)10 × outer ØTemperature range (fixed)-40...+80 °CTemperature range (mobile)-25...+80 °CCable identification056Cable Type5 (PUR schweißfunkenbeständig)Approval (cable)cRUus (AWM-Style 20549/10493); CE conformCable weight [g/m]48,40Material (wire)Cu wire, bareResistor (core)max. 26 Ω/km (20 °C)Single wire Ø (core)0.15 mmConstruction (core)42 × 0.15 mm (multi-strand wire class 6)Diameter (core)3 × 0.75 mm²AWGsimilar to AWG 18Material (wire isolation)PPMaterial property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-freeShore hardness (wire isolation)74 ±3 DWire-Ø incl. isolation1.7 mm ±5%Color/numbering of wiresbk numbered, gnye longitudinally stripedStranding combination3 wires twistedShieldnoMaterial (jacket)PURMaterial property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis-, microbial- and welding spark resistantShore hardness (jacket)58 ±3 DOuter-Ø (jacket)5.2 mm ±5%Color (jacket)yellowchemical resistancegood resistance to oil, gasoline and chemicals (EN 60811-404)thermal resistanceflame retardant UL, FT2, IEC 60332-1, IEC 60332-2-2, welding spark resistantNominal voltage300 V ACTest voltage2 500 V ACCurrent load capacityto DIN VDE 0298-4Temperature range (fixed)-40...+80 °C, (+90 °C at max. 10 000 operating hours)Temperature range (mobile)-25...+80 °C, (+90 °C at max. 10 000 operating hours)Bend radius (fixed)5 × outer ØBend radius (moving)10 × outer ØNo. of bending cycles (C-track)max. 10 Mio. (25 °C)Traversing distance (C-track)max. 5 m (horizontal)Travel speed (C-track)max. 3.3 m/sAcceleration (C-track)max. 5 m/s²Torsion stress±360°/mNo. of torsion cyclesmax. 1 Mio. (25 °C)Torsion speed35 cycles/minJacket ColoryellowTechnical DataOperating voltage24 V AC ±20% / DC ±25%Rated surge voltage0.8 kVOperating current per contactmax. 4 AMaterial groupIEC 60664-1, category ICurrent consumptionapprox. 12 mASwitch off peakmax. 55 VSwitch off delay timemax. 20 msLED displayyellowLocking of portsM2.5/M12 (recommended torque 0.4/0.6 Nm)Compression glandM12 (SW13)ProtectionIP67 inserted and tightened (EN 60529)Locking materialZinc die casting, matte nickel platedMaterialMSUD (PBT); M12 (PUR)suitable for corrugated tube (internal Ø)10 mmHousingBlack plastic (gray on request)General dataPollution Degree3Temperature range-25...+85 °C, depending on cable qualityCommercial datacountry of originCZcustoms tariff number85444290EAN4048879416160eClass27279218Packaging unit1 |
| Raggio di curvatura (in movimento) | 10 × outer Ø |
| Identificazione dei cavi | 056 |
| Capacità di carico attuale | to DIN VDE 0298-4 |
| Numero di cicli di torsione | max. 1 Mio. (25 °C) |
| Numero/diametro dei fili | 3 × 0.75 mm² |
| Ø filo singolo (nucleo) | 0.15 mm |
| Combinazione di spiaggiamento | 3 wires twisted |
| Tempo di ritardo di spegnimento | max. 20 ms |
| numero della tariffa doganale | 85444290 |
| Accelerazione (C-track) | max. 5 m/s² |
| Velocità di marcia (binario C) | max. 3.3 m/s |
| Durezza Shore (rivestimento) | 58 ±3 D |
| Diametro del filo incl. isolamento | 1.7 mm ±5% |
| Colore/numerazione dei fili | bk numbered, gnye longitudinally striped |
| Materiale (isolamento del filo) | PP |
| Intervallo di temperatura (fisso) | -40...+80 °C |
| Proprietà del materiale (rivestimento) | CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis-, microbial- and welding spark resistant |
| Intervallo di temperatura (mobile) | -25...+80 °C |
| Corrente di esercizio per contatto | max. 4 A |
| Distanza di attraversamento (binario C) | max. 5 m (horizontal) |
| Numero di cicli di piegatura (C-track) | max. 10 Mio. (25 °C) |
| Durezza Shore (isolamento del filo) | 74 ±3 D |
| Proprietà del materiale (isolamento del filo) | CFC-, halogen-, cadmium-, silicone- and lead-free |
| adatto per tubo corrugato (Ø interno) | 10 mm |