| Parametro | Valore |
|---|---|
| AWG | similar to AWG 22 |
| EAN | 4048879166188 |
| Modulo | 40461 |
| Codifica | A-coded |
| Scudo | no |
| eClass | 27279218 |
| Art.No.: | 7000-40461-2530100 |
| Materiale | PUR |
| Ø esterno | 4.3 mm ±5% |
| Standard | DIN EN 61076-2-101 (M12) |
| Tipo di cavo | 5 (PUR schweißfunkenbeständig) |
| Protezione | IP65, IP66K, IP67 inserted and tightened (EN 60529) |
| display a LED | LED (yellow/green) |
| Colore della giacca | gray |
| Numero di pali | 3-/4-pole |
| Tensione di prova | 2 500 V AC |
| Velocità di torsione | 35 cycles/min |
| Colore (giacca) | gray |
| Gruppo di materiali | IEC 60664-1, category I |
| Unità di imballaggio | 1 |
| sforzo di torsione | ±360°/m |
| Isolamento dei fili | PP (br, bl, bk) |
| Diametro (nucleo) | 3 × 0.34 mm² |
| Materiale (filo) | Cu wire, bare |
| Metodo di montaggio | inserted, tightened |
| Tensione nominale | 300 V AC |
| Resistore (nucleo) | max. 60 Ω/km (20 °C) |
| Approvazione (cavo) | cRUus (AWM-Style 20549/10493); CE conform |
| Materiale di bloccaggio | Zinc die casting, matte nickel plated |
| Blocco delle porte | Screw thread M12 × 1 mm (recommended torque 0.6 Nm) self-securing |
| Grado di inquinamento | 3 |
| Ghiandola di compressione | M12 (SW13) |
| Materiale (guarnizione) | FKM |
| Materiale (giacca) | PUR (UL/CSA), welding spark |
| Tensione di esercizio | 24 V DC ±25% |
| Ø esterno (rivestimento) | 4.3 mm ±5% |
| Intervallo di temperatura | -25...+85 °C, depending on cable quality |
| paese di origine | DE |
| Proprietà del binario C | 10 Mio. |
| Peso del cavo [g/m] | 29,70 |
| Materiale (contatto) | Copper alloy |
| resistenza termica | flame retardant UL, FT2, IEC 60332-1, IEC 60332-2-2, welding spark resistant |
| Raggio di curvatura (fisso) | 5 × outer Ø |
| Costruzione (nucleo) | 42 × 0.1 mm (multi-strand wire class 6) |
| Tensione di sovratensione nominale | 0.8 kV |
| resistenza chimica | good resistance to oil, gasoline and chemicals (EN 60811-404) |
| Prodotto alternativo: | Product ComparisonMale 90° – female 90°M12 – M123-/4-polebridged2 × LED (PNP), (NPN) on requestArt-No. 7005 - M12 Lite - (plastic hexagonal screw) on requestPlastic housings with good resistance against chemicals and oils. The resistance to aggressive media should be individually tested for your application. Further details on request. Further cable lengths on request.FormForm40461CablesNo./diameter of wires3 × 0.34 mm²Wire isolationPP (br, bl, bk)C-track properties10 Mio.Material (jacket)PUR (UL/CSA), welding sparkOuter Ø4.3 mm ±5%Bend radius (moving)10 × outer ØTemperature range (fixed)-40...+80 °CTemperature range (mobile)-25...+80 °CCable identification253Cable Type5 (PUR schweißfunkenbeständig)Approval (cable)cRUus (AWM-Style 20549/10493); CE conformCable weight [g/m]29,70Material (wire)Cu wire, bareResistor (core)max. 60 Ω/km (20 °C)Single wire Ø (core)0.1 mmConstruction (core)42 × 0.1 mm (multi-strand wire class 6)Diameter (core)3 × 0.34 mm²AWGsimilar to AWG 22Material (wire isolation)PPMaterial property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-freeShore hardness (wire isolation)74 ±3 DWire-Ø incl. isolation1.25 mm ±5%Color/numbering of wiresbr, bk, blStranding combination3 wires twistedShieldnoMaterial (jacket)PURMaterial property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis-, microbial- and welding spark resistantShore hardness (jacket)58 ±3 DOuter-Ø (jacket)4.3 mm ±5%Color (jacket)graychemical resistancegood resistance to oil, gasoline and chemicals (EN 60811-404)thermal resistanceflame retardant UL, FT2, IEC 60332-1, IEC 60332-2-2, welding spark resistantNominal voltage300 V ACTest voltage2 500 V ACCurrent load capacityto DIN VDE 0298-4Temperature range (fixed)-40...+80 °C, (+90 °C at max. 10 000 operating hours)Temperature range (mobile)-25...+80 °C, (+90 °C at max. 10 000 operating hours)Bend radius (fixed)5 × outer ØBend radius (moving)10 × outer ØNo. of bending cycles (C-track)max. 10 Mio. (25 °C)Traversing distance (C-track)max. 5 m (horizontal)Travel speed (C-track)max. 3.3 m/sAcceleration (C-track)max. 5 m/s²Torsion stress±360°/mNo. of torsion cyclesmax. 1 Mio. (25 °C)Torsion speed35 cycles/minJacket ColorgrayTechnical DataOperating voltage24 V DC ±25%Operating voltage (only UL listed)max. 30 V DCRated surge voltage0.8 kVOperating current per contactmax. 4 ANo. of poles3-/4-poleMaterial groupIEC 60664-1, category ICodingA-codedLED displayLED (yellow/green)Locking of portsScrew thread M12 × 1 mm (recommended torque 0.6 Nm) self-securingCompression glandM12 (SW13)ProtectionIP65, IP66K, IP67 inserted and tightened (EN 60529)Locking materialZinc die casting, matte nickel platedMaterialPURsuitable for corrugated tube (internal Ø)10 mmGeneral dataStandardsDIN EN 61076-2-101 (M12)Mounting methodinserted, tightenedMaterial (contact)Copper alloyMaterial (contact surface)AuMaterial (gasket)FKMPollution Degree3Temperature range-25...+85 °C, depending on cable qualityCommercial datacountry of originDEcustoms tariff number85444290EAN4048879166188eClass27279218Packaging unit1 |
| Raggio di curvatura (in movimento) | 10 × outer Ø |
| Identificazione dei cavi | 253 |
| Capacità di carico attuale | to DIN VDE 0298-4 |
| Numero di cicli di torsione | max. 1 Mio. (25 °C) |
| Numero/diametro dei fili | 3 × 0.34 mm² |
| Ø filo singolo (nucleo) | 0.1 mm |
| Combinazione di spiaggiamento | 3 wires twisted |
| numero della tariffa doganale | 85444290 |
| Accelerazione (C-track) | max. 5 m/s² |
| Velocità di marcia (binario C) | max. 3.3 m/s |
| Durezza Shore (rivestimento) | 58 ±3 D |
| Diametro del filo incl. isolamento | 1.25 mm ±5% |
| Colore/numerazione dei fili | br, bk, bl |
| Materiale (isolamento del filo) | PP |
| Intervallo di temperatura (fisso) | -40...+80 °C |
| Materiale (superficie di contatto) | Au |
| Proprietà del materiale (rivestimento) | CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis-, microbial- and welding spark resistant |
| Intervallo di temperatura (mobile) | -25...+80 °C |
| Corrente di esercizio per contatto | max. 4 A |
| Distanza di attraversamento (binario C) | max. 5 m (horizontal) |
| Numero di cicli di piegatura (C-track) | max. 10 Mio. (25 °C) |
| Durezza Shore (isolamento del filo) | 74 ±3 D |
| Proprietà del materiale (isolamento del filo) | CFC-, halogen-, cadmium-, silicone- and lead-free |
| Tensione di esercizio (solo omologata UL) | max. 30 V DC |
| adatto per tubo corrugato (Ø interno) | 10 mm |
Specifiche tecniche e dati di prestazione
Guida di installazione e utilizzo